Explanation
The data set specified in the DD statement preceding
this message was not successfully retrieved from the associated data
set stream for the reason indicated by the condition code.
In
the message text:
- ccc
- the condition code, as follows:
- Code
- Explanation
- 132
- The operator replied ‘GO’ after messages IEB545, IEB546, and IEB547
were issued describing this data set.
- 202
- Requested data set was found but operator did not successfully
supply the volume accessibility qualifier.
- 204
- Requested data set was found, but operator did not successfully
supply the data set security qualifier.
- 212
- Requested data set id described by an incorrect HDR1 label. Message
IEB531I indicates possible causes.
- 216
- Requested data set was found, but permanent I/O error occurred
while priming buffers.
- 224
- A volume sequence error was detected while attempting to open
the data set. The operator replied ‘C’ to message IEB540D.
- 228
- The VOLSER specified in JCL was found, but it did not contain
the requested data set. If there were duplicate VOLIDs in an ADS stream,
the first volume encountered with a given identifier must contain
data sets specifying that VOLID or this message results.
- 300
- Requested data set was found and opened, but an error was encountered
while reading the data set.
- 310
- Requested data set was found and opened, but an incorrect VOL1
label was encountered in EOV processing for a multivolume data set.
Message IEB530I indicates possible reasons the VOL1 label was incorrect.
- 312
- Requested data set was found and opened, but an incorrect HDR1
label was encountered in EOV processing for a multivolume data set.
Message IEB531I indicates possible reasons the HDR1 label was incorrect.
- 316
- Requested data set was found and opened, but a permanent I/O error
occurred while reading the data set.
- 320
- Requested data set was found and opened, but a delimiter diskette
was encountered while reading the data set.
- 324
- Requested data set was found and opened, but during EOV processing
of a multivolume data set, the operator replied ‘C’ to message IEB540A.
- 408
- The volume identifier specified in JCL was incorrect as a volume
identifier for a diskette.
System action
Processing was discontinued for data set specified
by the data set identifier. The job requesting the data set will be
run TYPRUN=SCAN in order to pass this message back to the programmer
as a JCL comment statement.
Programmer response
Correct the problem indicated by the return
code and resubmit the job.
Source
Routing code
Descriptor code