IEB19DI
MEMBER member {COPIED | LOADED}, FORMAT IS SCATTER-LOAD |, AND IS A NEW NAME

Explanation

COPYMOD has been specified. The member is a renamed load module which has been copied to the output data set with no change in block size or content. The link edit attributes of the member make it ineligible for processing by COPYMOD.

The old name of this member can be determined by checking the IEBCOPY control statements printed at the beginning of the copy step in which this message occurred.

In the message text:
member
The specified member.

The severity is 4.

System action

The member was copied unaltered.

System programmer response

The AMBLIST utility may be used to check the link edit attributes of member.

Programmer response

Process the module using the link editor.

Source