IEBA14I
PARAMETER(S) INVALID FOR KEYWORD (keywd).

Explanation

Parameters for the indicated keyword have been incorrectly specified. There are too many characters, or too many parameters, or incorrect parameter specification. It may also mean that the number of lines described by the LPI keyword exceeds the length of the form as described by LINES or SIZE.

In the message text:
keywd
The specified keyword.

System action

The IEBIMAGE program continues processing the next control statement, but writing to the library data set for the current operation is inhibited.

System programmer response

If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output, the source input for the job, and all printed output and output data sets related to the problem.

Programmer response

Correct the parameter specifications and resubmit the job.

Source

DFSMSdfp