IEE174I (form 22 of 36)
hh.mm.ss DISPLAY M idr
text

Explanation

Where text is:
CONTROL UNIT CCCC
CHP                   nn  nn  nn  nn
DEST LINK ADDRESS     la  la  la  la
ENTRY LINK ADDRESS    la  la  la  la
CHP PHYSICALLY ONLINE Y|N Y|N Y|N Y|N
PATH VALIDATED        Y|N Y|N Y|N Y|N
MANAGED               Y|N Y|N Y|N Y|N
ZHPF-CHPID            Y|N Y|N Y|N Y|N
ZHPF-CU INTERFACE     Y|N Y|N Y|N Y|N
MAXIMUM MANAGED CHPID(S) ALLOWED  =n
DESTINATION CU LOGICAL ADDRESS  =da
CU ND                 =tttttt.mmm.nnn.pp.ssssssssssss.uuuu
CU NED                =tttttt.mmm.nnn.pp.ssssssssssss.uuuu
TOKEN NED             =tttttt.mmm.nnn.pp.ssssssssssss.uuuu
FUNCTIONS ENABLED     = functions
CONTROL UNIT IS INELIGIBLE FOR DCM FOR THE FOLLOWING REASONS:
rsntext
DEFINED DEVICES          
dddd 
DEFIND PAV ALIASES        
aaaa 

A reconfiguration display request (a DISPLAY M=CU(xxxx) command or an internal request) asked the system to display the status of the control unit.

In the message text:
nn
A channel path (X'00' through X'FF' ) to the device. Under each nn is Y or N indicating whether the corresponding condition is true or not.
DEST LINK ADDRESS la
A 1-byte or 2-byte address of a control unit that is used to access the I/O device associated with the specified channel path. If 1 byte, it is the link address. If 2 bytes, the first byte is the switch address (domain) and the second byte is the destination port address (area). This information will only be displayed when the cascade facility is available.
ENTRY LINK ADDRESS la
A 1-byte or 2-byte physical link address of the channel path to the entry switch. If 1 byte, it is the link address. If 2 bytes, the first byte is the switch address (domain) and the second byte is the entry port address (area). This information will only be displayed when the cascade facility is available.
CHP PHYSICALLY ONLINE Y|N
The specified channel path is (Y) or is not (N) configured online to the hardware.
PATH VALIDATED Y|N
The I/O check of the paths to a device was successful (Y) or has failed (N).
MANAGED Y|N
The channel path is (Y) or is not (N) defined as managed. This line will be displayed only for a managed subsystem.
ZHPF-CHPID Y|N
The channel path supports (Y) or does not support (N) the High Performance FICON for System z (zHPF) facility.
ZHPF-CU INTERFACE Y|N
The control unit interface supports (Y) or does not support (N) the High Performance FICON for System z (zHPF) facility.
MAXIMUM MANAGED CHPID(S) ALLOWED=n
The maximum number of managed chips that can be used by the control unit.
DESTINATION CU LOGICAL ADDRESS=da
The logical link address of a control unit that is used to access the I/O device associated with the specified channel paths.
CCCC
The control unit that was specified.
CU ND
Node descriptor of the attached subsystem.
CU NED
Node-element descriptor
TOKEN NED
Node-element descriptor that was most recently obtained from the control unit.
FUNCTIONS ENABLED=functions
Displays the functions enabled for the control unit. The following functions may be displayed:
ZHPF
Indicates that High Performance FICON for System z (zHPF) facility is enabled for use.
CONTROL UNIT IS INELIGIBLE FOR DCM FOR THE FOLLOWING REASONS
If the control unit is a managed control unit, the control unit is ineligible for Dynamic Channel-path Management (DCM).

rsntext can be one or more of the following:

UNABLE TO RETRIEVE CONTROL UNIT NODE DESCRIPTOR
The node descriptor cannot be retrieved for the control unit
UNABLE TO RETRIEVE INFORMATION FROM CHANNEL SUBSYSTEM
Configuration information such as the list of channel paths and the maximum number of managed CHPIDs cannot be obtained from the channel subsystem for this control unit.
A DEVICE/CHPID MISMATCH EXISTS
The devices for this control unit have different sets of CHPIDs.
CONTROL UNIT NOT SUPPORTED BY DCM
This model of control unit is not supported by DCM.
UNABLE TO RETRIEVE NEIGHBOR NODE (SWITCH) INFORMATION
The node descriptor information for the switches connected to this control unit cannot be obtained.
CONTROL UNIT HAS A MIX OF ESCON/FCV AND FICON CHPIDS
The control unit has both online ESCON or FICON bridge (FCV) CHPIDs and online FICON CHPIDs.
CONTROL UNIT SHARES CHPIDS WITH MIXED CHPID CONTROL UNIT
The control unit shares CHPIDs directly or indirectly with another control unit that has both online ESCON or FICON bridge (FCV) CHPIDs and online FICON CHPIDs.
SENSEID I/O ERROR
A sense-id channel program, which is part of a set of channel programs used to obtain control unit interface information, encountered an I/O error.
SENSEID I/O RETURNED INCORRECT INFORMATION
A sense-id channel program returned incorrect information.
UNABLE TO RETRIEVE REQUIRED COMMAND CODES
A sense-id channel program did not contain the command codes required to continue.
READ NODE IDENTIFIER I/O ERROR
The read node identifier channel program that was used to retrieve the list of control unit interfaces failed.
CONTROL UNIT INTERFACE INFORMATION IS NOT VALID
The read node identifier channel program that was used to retrieve the list of control unit interfaces was successful, but the information returned was not valid.
INCONSISTENT MAXIMUM MANAGED CHPID COUNTS IN GROUP
The managed control units in the control unit group have different maximum managed CHPID counts. All managed control units in the group (control units with a non-zero maximum number of managed CHPIDs) must have the same value.
DEFINED DEVICES
dddd
A list of devices defined for the specified control unit are displayed.
DEFINED PAV ALIASES
aaaa
A list of PAV ALIASES defined for the specified control unit is displayed.
tttttt.mmm.nnn.pp.ssssssssssss.uuuu
These descriptors are made up of the following:
tttttt
Type number of the device.
mmm
Model number of the device.
nnn
Manufacturer identification code.
pp
Plant of manufacture number.
ssssssssssss
Sequence number, unique device number.
uuuu
Two-byte tag.

Routing code

-

Descriptor code

4