Explanation
Where
text is:
CONTROL UNIT CCCC
CHP nn nn nn nn
DEST LINK ADDRESS la la la la
ENTRY LINK ADDRESS la la la la
CHP PHYSICALLY ONLINE Y|N Y|N Y|N Y|N
PATH VALIDATED Y|N Y|N Y|N Y|N
MANAGED Y|N Y|N Y|N Y|N
ZHPF-CHPID Y|N Y|N Y|N Y|N
ZHPF-CU INTERFACE Y|N Y|N Y|N Y|N
MAXIMUM MANAGED CHPID(S) ALLOWED =n
DESTINATION CU LOGICAL ADDRESS =da
CU ND =tttttt.mmm.nnn.pp.ssssssssssss.uuuu
CU NED =tttttt.mmm.nnn.pp.ssssssssssss.uuuu
TOKEN NED =tttttt.mmm.nnn.pp.ssssssssssss.uuuu
FUNCTIONS ENABLED = functions
CONTROL UNIT IS INELIGIBLE FOR DCM FOR THE FOLLOWING REASONS:
rsntext
DEFINED DEVICES
dddd
DEFIND PAV ALIASES
aaaa
A reconfiguration display
request (a DISPLAY M=CU(xxxx) command or an internal
request) asked the system to display the status of the control
unit.
In the message text:
- nn
- A channel path (X'00' through X'FF' ) to the
device. Under each nn is Y or N indicating whether
the corresponding condition is true or not.
- DEST LINK ADDRESS la
- A 1-byte or 2-byte address of a control unit that is used to access
the I/O device associated with the specified channel path. If 1 byte,
it is the link address. If 2 bytes, the first byte is the switch
address (domain) and the second byte is the destination port address
(area). This information will only be displayed when the cascade facility
is available.
- ENTRY LINK ADDRESS la
- A 1-byte or 2-byte physical link address of the channel path to
the entry switch. If 1 byte, it is the link address. If 2 bytes,
the first byte is the switch address (domain) and the second byte
is the entry port address (area). This information will only be displayed
when the cascade facility is available.
- CHP PHYSICALLY ONLINE Y|N
- The specified channel path is (Y) or is not (N) configured online
to the hardware.
- PATH VALIDATED Y|N
- The I/O check of the paths to a device was successful (Y) or has
failed (N).
- MANAGED Y|N
- The channel path is (Y) or is not (N) defined as managed. This
line will be displayed only for a managed subsystem.
- ZHPF-CHPID Y|N
- The channel path supports (Y) or does not support (N) the High
Performance FICON for System z (zHPF) facility.
- ZHPF-CU INTERFACE Y|N
- The control unit interface supports (Y) or does not support (N)
the High Performance FICON for System z (zHPF) facility.
- MAXIMUM MANAGED CHPID(S) ALLOWED=n
- The maximum number of managed chips that can be used by the control
unit.
- DESTINATION CU LOGICAL ADDRESS=da
- The logical link address of a control unit that is used to access
the I/O device associated with the specified channel paths.
- CCCC
- The control unit that was specified.
- CU ND
- Node descriptor of the attached subsystem.
- CU NED
- Node-element descriptor
- TOKEN NED
- Node-element descriptor that was most recently obtained from the
control unit.
- FUNCTIONS ENABLED=functions
- Displays the functions enabled for the control unit. The following
functions may be displayed:
- ZHPF
- Indicates that High Performance FICON for System z (zHPF) facility
is enabled for use.
- CONTROL UNIT IS INELIGIBLE FOR DCM FOR THE FOLLOWING REASONS
- If the control unit is a managed control unit, the control unit
is ineligible for Dynamic Channel-path Management (DCM).
rsntext can
be one or more of the following:
- UNABLE TO RETRIEVE CONTROL UNIT NODE DESCRIPTOR
- The node descriptor cannot be retrieved for the control unit
- UNABLE TO RETRIEVE INFORMATION FROM CHANNEL SUBSYSTEM
- Configuration information such as the list of channel paths and
the maximum number of managed CHPIDs cannot be obtained from the channel
subsystem for this control unit.
- A DEVICE/CHPID MISMATCH EXISTS
- The devices for this control unit have different sets of CHPIDs.
- CONTROL UNIT NOT SUPPORTED BY DCM
- This model of control unit is not supported by DCM.
- UNABLE TO RETRIEVE NEIGHBOR NODE (SWITCH) INFORMATION
- The node descriptor information for the switches connected to
this control unit cannot be obtained.
- CONTROL UNIT HAS A MIX OF ESCON/FCV AND FICON CHPIDS
- The control unit has both online ESCON or FICON bridge (FCV) CHPIDs
and online FICON CHPIDs.
- CONTROL UNIT SHARES CHPIDS WITH MIXED CHPID CONTROL UNIT
- The control unit shares CHPIDs directly or indirectly with another
control unit that has both online ESCON or FICON bridge (FCV) CHPIDs
and online FICON CHPIDs.
- SENSEID I/O ERROR
- A sense-id channel program, which is part of a set of channel
programs used to obtain control unit interface information, encountered
an I/O error.
- SENSEID I/O RETURNED INCORRECT INFORMATION
- A sense-id channel program returned incorrect information.
- UNABLE TO RETRIEVE REQUIRED COMMAND CODES
- A sense-id channel program did not contain the command codes required
to continue.
- READ NODE IDENTIFIER I/O ERROR
- The read node identifier channel program that was used to retrieve
the list of control unit interfaces failed.
- CONTROL UNIT INTERFACE INFORMATION IS NOT VALID
- The read node identifier channel program that was used to retrieve
the list of control unit interfaces was successful, but the information
returned was not valid.
- INCONSISTENT MAXIMUM MANAGED CHPID COUNTS IN GROUP
- The managed control units in the control unit group have different
maximum managed CHPID counts. All managed control units in the group
(control units with a non-zero maximum number of managed CHPIDs) must
have the same value.
- DEFINED DEVICES
- dddd
- A list of devices defined for the specified control unit are displayed.
- DEFINED PAV ALIASES
- aaaa
- A list of PAV ALIASES defined for the specified control unit
is displayed.
- tttttt.mmm.nnn.pp.ssssssssssss.uuuu
- These descriptors are made up of the following:
- tttttt
- Type number of the device.
- mmm
- Model number of the device.
- nnn
- Manufacturer identification code.
- pp
- Plant of manufacture number.
- ssssssssssss
- Sequence number, unique device number.
- uuuu
- Two-byte tag.
Routing code
Descriptor code