IEE407D
SLIP ID=xxxx text RESPECIFY TARGETID KEYWORD OR 'CANCEL'

Explanation

The system did not activate the first SLIP trap in a dynamic PER activation chain because the TARGETID parameter of one trap was incorrect. In the message text:
xxxx
The SLIP trap identifier specified on the SLIP command with the incorrect TARGETID parameter.
text
The reason the TARGETID was not correct is one of the following:
TARGETID CAUSES A CIRCULAR DYNAMIC PER ACTIVATION CHAIN.
The TARGETID of one trap in the chain references another trap that, in turn, refers back to the first trap, directly or indirectly.
TARGETID CORRESPONDS TO A nnnn TRAP.
Where nnnn is one of the following:
  • SUBTRAP
  • IGNORE
  • NON-PER

These traps do not participate in dynamic PER activation chains.

System action

The system does not active the SLIP traps in the dynamic PER activation chain. The system continues with other processing.

Operator response

Contact the system programmer.

System programmer response

Correct the problem indicated by the text. Ask the operator to enter the SLIP commands again.

Source

SLIP

Module

IEECB905

Routing code

-

Descriptor code

5