IEE366I
NO SMF DATA SETS AVAILABLE -- DATA BEING BUFFERED TIME = hh.mm.ss

Explanation

The current SMF data set is full. The system could not find an available SMF data set. As a result, SMF will put the SMF data in a buffer until a data set is available. This condition developed because the SYS1.MANn data sets were not dumped in response to message IEE362A. This message is also issued in response to a DISPLAY SMF command when no SMF data sets are available.

In the message text:
hh.mm.ss
The time given as the hour (00-23), the minute (00-59), and the second (00-59).

System action

System processing continues, but SMF buffers all SMF records. SMF counts the number of records it buffered and logs the starting and ending times when it was unable to write any records. When a data set does become available, SMF writes an SMF data lost record (type 7) to the available data set and then writes the buffered SMF records to the data set.

Operator response

Run the SMF dump program. If a dump program is currently running, make sure that it completes as soon as possible.

Source

System Management Facilities (SMF)

Module

IEEMB829

Routing code

4

Descriptor code

2