IEE634I
SWITCH xxxx, PORT yy, IS A CHPID PORT

, IS NOT IMPLEMENTED
, IS NOT INSTALLED
, IS NOT ATTACHED
, IS PORT STATE OFFLINE
, IS SYSTEM STATE INELIGIBLE
, IS INELIGIBLE FOR DCM
, FAILS VERIFICATION

Explanation

A VARY SWITCH command requested that a port or ports be varied ONLINE or OFFLINE to dynamic channel path management. The request could not be carried out because of the reason given.

Rejection explanations:
IS A CHPID PORT
This port is connected to a channel path. Only ports connected to subsystems may be varied ONLINE or OFFLINE to dynamic channel path management.
IS NOT IMPLEMENTED
This port is outside the range of switch ports for this model.
IS NOT INSTALLED
The port is within the range of implemented ports for the model but it is not physically present at your installation.
IS NOT ATTACHED
This port is installed but is not presently connected to any element.
IS PORT STATE OFFLINE
This port is offline to dynamic channel path management due to its state (for example, it is blocked dedicated, or offline)
IS SYSTEM STATE INELIGIBLE
This port is offline because the system has determined that it is unavailable for dynamic channel path management.
IS INELIGIBLE FOR DCM
This port cannot be varied because it is not attached to a DASD subsystem.
FAILS VERIFICATION
This port cannot be varied because the specified switch device number is not a switch or cannot be determined.

System action

If a range of ports was specified, action may have been taken only on the valid ports.

Operator response

If this message is unexpected for a particular port, then correct the original condition. Once the failing condition is corrected, dynamic channel path management will begin managing the port as requested.

Source

Input/Output Supervisor (IOS)

Module

IOSVVSWR, IOSVVSWP, IEEVCONF