IEA823I
IEASVCxx: SVCnum: text

Explanation

An SVC number was incorrectly specified in the IEASVCxx parmlib member. text is one of the following:

In the message text:
xx
The suffix of the IEASVCxx parmlib member
num
The SVC number that was incorrectly specified
text
Describes the error. text is one of the following:
SYNTAX ERROR AT parm
Where parm is a character string in the SVCnum specification.
UNBALANCED PARENTHESIS AT parm
Where parm is a keyword specification.
TYPE t SVC CANNOT GET GLOBAL SPIN LOCK
Where t is the SVC type specification.
TYPE 6 SVC CANNOT GET ANY LOCK
A type 6 SVC cannot request any locks, but it did.
CANNOT REQUEST CMS LOCK WITHOUT LOCAL LOCK
An SVC cannot request the cross memory services (CMS) lock without first obtaining the local lock, but an SVC tried to do this.

System action

The system ignores the statement.

System programmer response

Check the statements in the IEASVCxx parmlib member for syntax problems.

Source

Supervisor control

Module

IEAVNP25

Routing code

2,10

Descriptor code

4