IEA457I
TRACK FORMAT NOT SUPPORTED FOR PAGING - ss.p-xx-xx SENSE=sense

Explanation

The 3880 Storage Control Model 11 or 21 detected an incorrect track format or no-record-found error. In the message text:
ss.p-xx-xx
The physical identifier of the reporting storage director.
sense
The 32 characters of sense data reported by the device.
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

System action

The error recovery procedure (ERP) reissues the channel command words (CCW) that failed.

Operator response

Notify the system programmer.

System programmer response

If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Programmer response

Format the paging packs attached to the paging storage director of the 3880 Model 11 or 21.

Source

DFSMSdfp

Module

IGGSNS01

Routing code

1,6

Descriptor code

4