IEA379I
VIODSN=dsname,DATA SET NOT CATALOGED - reg15

Explanation

The data set name specified in the VIODSN parameter in IEASYSxx could not be located in the system catalog.

The message text, reg15 is the value returned from SVC 26 in Register 15.

System action

Message IEA377D is issued. If the operator replies with a new data set name, the system processes the data set. If the operator replies IGNORE, or gives a null reply, message IEA378I is displayed and the IPL continues. The system will reject journaling requests for VIO data sets.

Operator response

Reply to message 377D with VIO journaling data set name or IGNORE.

System programmer response

If VIO journaling is required, supply the VIO journaling data set name in the VIODSN parameter of IEASYSxx before the next IPL.

Source

Auxiliary Storage Manager (ASM)

Module

ILRASRM2

Routing code

Note 9

Descriptor code

4