IEA345A
dsname NOT USED (text) - PRESS ENTER TO CONTINUE

Explanation

The system cannot use the specified parmlib data set.

In the message text:
dsname
The data set name.
text
A variable length text string that is one of the following:
OPEN FAILED
The system cannot open data set dsname.
volser NOT FOUND
The system cannot locate or cannot mount volume volser.
NOT CATALOGED
The LOADxx parmlib statement for data set dsname was not cataloged in the master catalog.

System action

IPL processing waits for the operator to press ENTER.

Operator response

Notify the system programmer. To continue the IPL without data set dsname, press ENTER.

System programmer response

Depends on text:
OPEN FAILED
Ensure that dsname either resides on the volume specified on the LOADxx parmlib statement or is cataloged in the master catalog. IPL the system again to use the data set.
volser NOT FOUND
Ensure that the volume exists and it is mounted. IPL the system again to use the data set.
NOT CATALOGED
Ensure that the data set dsname is cataloged on the master catalog or specify a volume for it on the LOADxx parmlib statement. IPL the system again to use the data set.

Source

Nucleus initialization program (NIP)

Module

IEAVNPOP