IEA282I
text

Explanation

Where text is one of the following messages:

hh.mm.ss ETR STATUS SYNCHRONIZATION
MODE=mode CPC SIDE=n
[CPC PORT 0 [<==] active [==>] CPC PORT 1
op                    op
enb                  enb
[CPC PORT 0 [<==] active [==>] CPC PORT 1
op        op
enb      enb
ETR NET ID=etrnet   ETR NET ID=etrnet
ETR PORT=etrport    ETR PORT=etrport
ETR ID=etrid            ETR ID=etrid

[THE ETR FACILITY IS NOT INSTALLED.]

[PORT STATUS CANNOT BE DETERMINED.]

[ETR DATA COULD NOT BE OBTAINED FOR CPC
PORT 0]

[ETR DATA COULD NOT BE OBTAINED FOR CPC
PORT 1]

Or

hh.mm.ss ETR STATUS  ETR SIMULATION MODE,
SIMETRID=nn

Or

[THIS SERVER IS PART OF TIMING NETWORK ctnid]

All messages are in response to the DISPLAY ETR command.

ETR is the MVS™ generic name for the IBM® Sysplex Timer (9037) or equivalent.

In the first message text:
hh.mm.ss
The hour (00-23), minute (00-59), and second (00-59) that the system issued this message.
mode
The current synchronization mode, as follows:
ETR
The system time-of-day (TOD) clocks are synchronized to an External Time Reference (ETR).
LOCAL
The operator set the system TOD clocks. The system TOD clocks are synchronized to a local oscillator.
<==
==>
An arrow pointing to the active ETR port.
op
The operational status of the ETR port, as follows:
OPERATIONAL
The port is working.
NONOPERATIONAL
The port is not working.
enb
One of the following:
ENABLED
MVS has enabled the port.
DISABLED
MVS has disabled the port.
etrnet
The ETR network identifier, in decimal.
etrport
The ETR port number, in decimal.
etrid
The ETR identifier, in decimal.
THE ETR FACILITY IS NOT INSTALLED
There is no ETR installed on the system.
PORT STATUS CANNOT BE DETERMINED
The system cannot communicate with the ETR.
The second message text is displayed if SIMETRID=nn in CLOCKxx is specified. In the second message text:
hh.mm.ss
The hour (00-23), minute (00-59), and second (00-59) that the system issued this message.
nn
The simulated sysplex timer identifier ranging from X'00' to X'1F'.

System action

The system continues processing.

Operator response

None.

System programmer response

None.

Source

Timer supervision

Module

IEATDISP

Routing code

*

Descriptor code

5