Explanation
If this message is preceded by message IEA013E,
one of the following occurred:
- The system found an error in a parameter or parameter value in
one or more IEASYMxx parmlib members that were used during IPL.
- The system could not find an IEASYMxx member specified in LOADxx
parmlib member.
Otherwise, the system found a syntax error in the IEASYMxx
parmlib member.
The system issues this message only for statements
in IEASYMxx that apply to the processor or LPAR on which this system
is being initialized.
System action
The system issues this message on the nucleus
initialization program (NIP) console and waits for the operator to
respond. The system discards any processing of IEASYMxx members that
occurred before the error. The system might issue messages that describe
the error prior to issuing this message, as described in the message
explanation.
System programmer response
Do one of the following:
- If you want to respecify the IEASYMxx members, enter all the
suffixes of the IEASYMxx members in response to this message. (For
example, if you specified three IEASYMxx suffixes and only one was
not valid, you must respecify the two valid suffixes, and replace
or remove the suffix that was not valid.)
- Reply U to bypass IEASYMxx processing and continue with
system initialization.
Source
System initialization (IPL/NIP)
Module
Routing code
Descriptor code