EDG4037I
VOLUME volser REJECTED. FILE BEING CREATED DOES NOT FOLLOW LAST FILE RECORDED

Explanation

The data set created on the specified output volume does not follow the last data set recorded in the DFSMSrmm control data set. The data sets must be recorded in sequence. The information recorded by DFSMSrmm might be incorrect, or the request might not be valid because intervening data sets have not yet been written.

In the message text:
volser
Volume serial number

System action

If DFSMSrmm is operating in warning mode, the volume specified in this message can be used and DFSMSrmm issues message EDG4004I. If DFSMSrmm is operating in protect mode, DFSMSrmm issues message EDG4005E or EDG4006E.

Operator response

None.

System programmer response

If the volume has been correctly rejected, no action is necessary. If the volume was rejected because of incorrect DFSMSrmm control data set information, update the DFSMSrmm control data set, using known information for the data sets that have not yet been recorded by DFSMSrmm. If this message is accompanied by system completion code F13, see z/OS DFSMSrmm Implementation and Customization Guide for more information.