z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG2106D

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG2106D
JOURNAL AND CONTROL DATASET DO NOT MATCH - REPLY "C" TO CANCEL, "D" TO DISABLE OR "L" TO LOCK

Explanation

During initialization, the DFSMSrmm subsystem found that the journal does not match the current control data set because
  • The control data set was restored without using the journal
or
  • The journal selected by the DFSMSrmm parameters has changed and is not empty

System action

The current task waits for a reply.

Operator response

Reply as described in the following table.

When the operator replies For the action The result is
C Cancel DFSMSrmm stops.
D Disable DFSMSrmm disables the journal and completes initialization. Updates can be made to the DFSMSrmm control data set, but no further updates to the journal take place until the BACKUP function of inventory management is run to back up the control data set and to clear the journal.
L Lock DFSMSrmm completes its initialization but no updates to the DFSMSrmm control data set are allowed until the DFSMSrmm EDGHSKP utility with the BACKUP parameter is run to back up the control data set and to clear the journal.
Any reply other than C, L, or D. Other than CANCEL, LOCK, or DISABLE. DFSMSrmm reissues this message to prompt the operator for the correct response: C, L, or D.

System programmer response

Instruct the operator to respond as follows:

If the mismatch The operator reply is
is caused by an incomplete restore C. Then repeat the restore using both the control data set backup and the correct journal, then restart DFSMSrmm.
is caused by an incorrect journal C. Then restart DFSMSrmm with the correct journal.
cannot be resolved immediately L or D. Then request an inventory management - BACKUP of the DFSMSrmm control data set. Clear the journal to avoid possible data integrity problems that might occur when DFSMSrmm control data set updates are not journaled.

You must reply to this message before the DFSMSrmm control data set can be backed up. The control data set remains reserved until you reply to this message.

Source

DFSMSrmm

Module

EDGMFIO

Routing code

1,3

Descriptor code

2

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014