EDG0127D RECOVERY OF CONTROL DATA SET ON date AT time POSSIBLY
INCOMPLETE - REPLY "CONTINUE" OR "CANCEL" ExplanationDFSMSrmm found that the recovery of the control data set by EDGBKUP at the time and date specified was not successful. There might be inconsistencies in the DFSMSrmm control data set. In
the message text:
System actionDFSMSrmm prompts the operator to reply whether initialization of the DFSMSrmm address space should continue or be canceled. Operator responseReply as directed by the system programmer. System programmer responseVerify the contents of the DFSMSrmm control data set, using the EDGUTIL utility, PARM=VERIFY, to determine if any inconsistencies exist in the control data set. If the records containing the inconsistencies refer to volumes that are not critical to the installation, instruct the operator to reply CONTINUE. Otherwise, instruct the operator to reply CANCEL, and perform the corrective actions recommended by the EDGUTIL messages to correct the DFSMSrmm control data set. SourceDFSMSrmm ModuleEDGAMGR Routing code1,3 Descriptor code2 |