z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ERB301I

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

ERB301I
sid: CONFLICTING OPTIONS - n

Explanation

For session sid, you specified incorrect values or mutually exclusive options. n indicates the type of conflict, as follows:
n
Conflict
1
Both NOREPORT and NORECORD were specified, meaning that RMF™ could produce no output data.
2
REPORT(DEFER) and NOSTOP were specified, meaning that the SYSOUT spool space could become filled.
3
The STOP value is less than the INTERVAL value, meaning that the session will end before the first measurement interval.
4
Both SYNC(SMF) and INTERVAL were specified, but the two options are mutually exclusive. When the SYNC(SMF) option is specified, the interval length is determined by SMF.

System action

RMF modifies the options and continues with input merge and initialization for the session. n indicates the modification:
n
Modification
1
RMF changes NOREPORT to REPORT(DEFER).
2
RMF changes NOSTOP to STOP(value) and sets the value equal to the length established for the interval.
3
RMF sets the STOP value equal to the length established for the interval.
4
RMF ignores the INTERVAL option and uses SYNC(SMF).

In addition, RMF asks the operator for intervention: RMF issues message ERB305I, listing the current session options, followed by message ERB306D, to which the operator replies by supplying new options or entering ‘GO’. RMF continues other processing.

Operator response

Examine the options following message ERB305I, and respond to message ERB306D.

System programmer response

Examine the input sources, and correct any errors before the next RMF session.

Source

Resource Measurement Facility™ (RMF)

Routing code

2

Descriptor code

4,5

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014