z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ERB253I

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

ERB253I
sid: ‘type’ RECORDS NO LONGER COLLECTED DUE TO {Scde | Ucde} ABEND IN DURATION INTERVAL date time

Explanation

While processing a duration report, the RMF™ Postprocessor detected an error. The Postprocessor may issue a user completion code Ucde; Scde is the system completion code.

The message indicates the date and start time of the duration interval during which the error occurred.

System action

If the error occurred during the data collecting phase, the Postprocessor stops collecting data for the type of duration report named in the message. If other duration reports were requested, the Postprocessor continues with them.

If the error occurred during the report writing phase, some or all of the reports for the duration interval indicated in the message may be lost. The Postprocessor continues to generate all types of duration reports.

System programmer response

Examine the dump, and respond to the completion code.

Source

Resource Measurement Facility™ (RMF)

Routing code

2

Descriptor code

4

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014