ERB114I
RMF: CANNOT LOAD LPA MODULES.

Explanation

RMF™ has detected that it cannot find required LPA modules. The RMF LPA modules reside in SYS1.SERBLPA. Possible causes for this error are as follows:
  • SYS1.SERBLPA is not in the LPALST concatenation.
  • LPALIB is defined as STEPLIB.

System action

The RMF control program terminates immediately.

Operator response

Inform the system programmer.

System programmer response

Make sure that library SYS1.SERBLPA is in the LPALST concatenation. This can be achieved by adding the library to the active LPALSTxx PARMLIB member (for details see the z/OS MVS Initialization and Tuning Reference) and RE-IPL.

To add the modules in SYS1.SERBLPA dynamically to the LPA without an IPL you may use the SETPROG or SET PROG=xx operator commands (see z/OS MVS System Commands).