z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6704E

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6704E
CDS USED IN THE MASTER DD STATEMENT IS THE SAME NAME AS THE CDS IN USE BY DFSMSrmm IN THIS SYSTEM

Explanation

The EDGUTIL MEND function detected that the control data set name used in the MASTER DD statement is the same name as the control data set currently in use by DFSMSrmm on this system.

System action

The utility ends. DFSMSrmm sets return code 12.

Operator response

None.

System programmer response

Do not use the EDGUTIL MEND function on a control data set that DFSMSrmm is using. Stop DFSMSrmm. Then back up the DFSMSrmm control data set before running the EDGUTIL MEND job again.

Source

DFSMSrmm

Module

EDGUTIL