z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6517I

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6517I
ERROR READING THE VOLUME CATALOG, RETURN CODE code REASON CODE reason_code

Explanation

The utility, EDGUTIL, is verifying the consistency of volume information in the DFSMSrmm control data set with the volume catalog. The utility has failed to read the volume catalog.

In the message text:
code
This is the return code that is set by the CBRXVOL macro.
reason_code
This is the reason code that is set by the CBRXVOL macro.

System action

Processing ends. A return code of 12 is set.

Operator response

None.

System programmer response

Refer to z/OS DFSMS OAM Planning, Installation, and Storage Administration Guide for Tape Libraries for a description of the codes. If you can identify the cause of the error from the return and reason codes explanation, correct the error and retry the VERIFY(VOLCAT) process. Otherwise, report this error to the IBM® Support Center.

Source

DFSMSrmm

Module

EDGUTIL

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014