z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6514I

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6514I
LOCATION NAME newloc IS NOT CONSISTENT WITH OLD LOCATION FIELD VALUE oldloc IN THE volser VOLUME RECORD

Explanation

The DFSMSrmm utility, EDGUTIL, is verifying the contents of the volume records in the DFSMSrmm control data set. It has found that the LOCATION name is not consistent with the value in the old LOCATION field in the volume record. This could have happened as a result of sharing the DFSMSrmm control data set with a lower level system, and not following the guidance provided for sharing the control data set.

In the message text:
newloc
This is the name of the location where the volume is currently. It can be: HOME, LOCAL, DISTANT, REMOTE, or a system-managed library name.
oldloc
This is the value of the old LOCATION field. It can be: LIBRARY, LOCAL, DISTANT, or REMOTE.
volser
This is the volume serial number of the volume with the inconsistent fields.

System action

Processing continues. A minimum return code of 0 is set.

Operator response

None.

System programmer response

You can use the DFSMSrmm TSO subcommands or the DFSMSrmm ISPF dialog to list detailed information for the volume record. Use the detailed information to determine the correct LOCATION for the volume. The inconsistency can be corrected by changing the volume information. Use DFSMSrmm ISPF dialog or the RMM CHANGEVOLUME subcommand to do this.

Source

DFSMSrmm

Module

EDGUTIL

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014