z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6502W

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6502W
entry_type1 ENTRY entry_value1 POINTED TO BY entry_type2 ENTRY entry_value2 DOES NOT EXIST

Explanation

The utility, EDGUTIL, is verifying the consistency of information in the DFSMSrmm control data set. The entry specified as entry_name1 refers to a non-existent entry, specified as entry_name2.

In the message text:
entry_type1
Type of DFSMSrmm control data set entry, which can be:
  • ASSIGNED BIN
  • DATASET
  • EMPTY BIN
  • EMPTY RACK
  • IN-USE RACK
  • OWNER
  • PRODUCT
  • SCRATCH RACK
  • UNKNOWN TYPE
  • VOLUME
  • VRS
entry_value1
The value defined in the DFSMSrmm control data set for entry_type1
entry_type2
Type of DFSMSrmm control data set entry, which can be:
  • ASSIGNED BIN
  • DATASET
  • EMPTY BIN
  • EMPTY RACK
  • IN-USE RACK
  • OWNER
  • PRODUCT
  • SCRATCH RACK
  • UNKNOWN TYPE
  • VOLUME
  • VRS
entry_value2
The value defined in the DFSMSrmm control data set for entry_type2

System action

Processing continues.

Operator response

None.

System programmer response

Identify the cause of the error using the DFSMSrmm TSO subcommands or DFSMSrmm ISPF dialog and correct the error. If VTS support is installed, you must run EDGUTIL on the system where VTS is installed. Re-run EDGUTIL on the correct system. If the error cannot be corrected, restore the DFSMSrmm control data set using the latest backup copy.

Source

DFSMSrmm

Module

EDGUTIL

Go to the previous page Go to the next page