z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6663D

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6663D
drive_number, REPLY "R" TO RETRY OR "F" TO FAIL THE REQUEST, OR "A" TO ACCEPT THE MOUNTED VOLUME

Explanation

During EDGINERS processing, DFSMSrmm detected an incorrect volume serial number in the VOL1 label of a mounted volume. The EXEC parameter WRONGLABEL has been specified and DFSMSrmm prompts the operator to reply. DFSMSrmm issues this message after issuing either message EDG6661E or EDG6662E.

In the message text:

drive_number
The tape drive number.

System action

EDGINERS waits for a reply from the operator.

Operator response

Reply as described in the following table.

To The operator replies And the result is
Accept the mounted volume A DFSMSrmm relabels the volume to the new volume serial number.
Fail the request F DFSMSrmm unloads the mounted volume and the request fails.
Retry to request R DFSMSrmm unloads the mounted volume and reissues the mount request message EDG6627A.

The EDGINERS utility does not search the entire DFSMSrmm control data set to identify the volume. EDGINERS attempts to read the volume record of the volume matching the volser read in the VOL1 label. You can use the RMM SEARCHVOLUME subcommand with the VOL1(mounted_vol1) operand to identify the volume that might have been mounted.

System programmer response

None.

Source

DFSMSrmm

Module

EDGINERS

Go to the previous page Go to the next page