z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6818E

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6818E
STACKED VOLUME volser HAS INITIALIZE ACTION SET

Explanation

You are running the DFSMSrmm EDGUTIL utility with the VERIFY parameter for volume information. DFSMSrmm found a stacked volume with an initialize action set. Stacked volumes cannot have the initialize action outstanding.

In the message text:

volser
This is the volume serial number of the stacked volume.

System action

EDGUTIL processing continues. For EDGUTIL VERIFY processing, DFSMSrmm sets a minimum return code of 4.

Operator response

None.

System programmer response

Clear the volume initialize action using the RMM CHANGEVOLUME volser INITIALIZE(NO) subcommand or run the EDGUTIL utility with the MEND parameter.

Source

DFSMSrmm

Module

EDGUTIL

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014