Start of change

CPO1285E   System system name and sysplex sysplex name not found on a managed CPC

Explanation

The ACTIVATE DEFINEDCAPACITY, DEACTIVATE DEFINEDCAPACITY, ACTIVATE GROUPCAPACITY, or DEACTIVATE GROUPCAPACITY command has been issued specifying the referenced values for the SYS and PLEX parameters. An LPAR reporting both names for the operating system running in it cannot be found. This can be because the LPAR information for all CPCs is not yet available, the LPAR containing the system is not accessible to the Provisioning Manager, the CPC containing the LPAR is not in the active domain configuration, or the values do not specify an existing system. The command is ignored.

User response

If the values specify an existing system, check that appropriate access rights are granted to the Provisioning Manager, the CPC the system is running on is part of the active domain configuration, and that the LPAR information is already available. Then retry the command. Otherwise correct the names for the SYS and PLEX parameters and retry the command.

End of change