CNZ2609I   RECURSIVE AUTO-REPLY DETECTED FOR MESSAGE msgid. AUTO-REPLY WILL NOT PROCESS THIS WTOR: rpid msgtxt [msgtxtcont]

Explanation

Auto-reply processing has Start of changeexceeded the number of times it can replyEnd of change to a WTOR using the same policy in one second. The most likely cause is that the auto-reply policy contains an invalid reply for this WTOR and the delay value is zero.

In the message text:
msgid
The message ID of the WTOR.
rpid
The reply ID of the WTOR.
msgtxt
The text of the WTOR.
msgtxtcont
The continuation of the WTOR text.

System action

Auto-reply processing does not occur for the WTOR.

Operator response

Notify your system programmer. The operator or an automation product must provide a reply to this WTOR.

System programmer response

Update the auto-reply policy to specify a valid reply to this WTOR.

Module

CNZS1WTO

Source

Consoles (SC1CK)

Routing Code

2, 10 or sent to hardcopy only.

Descriptor Code

4