z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


BPXB002E

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

BPXB002E
OCS REQUIRES TCP/IP TO BE ACTIVE. START TCP/IP OR HAVE THE SYSTEM ADMINISTRATOR UNCONFIGURE THE OCS NODES.

Explanation

Outboard Communication Server (OCS) received an indication that TCP/IP is not active. TCP/IP is required for OCS to operate.

System action

OCS waits for TCP/IP to become active. There may be up to a two-minute delay between TCP/IP activation and OCS node connection.

Operator response

Either start TCP/IP or have the system administrator shut down OCS by issuing the ocsconfig command to unconfigure all OCS nodes. If TCP/IP is active, notify the system programmer.

System programmer response

Verify that the TSO/E command OBEYFILE was issued to cause TCP/IP to read the TCP/IP profile dataset. Verify that the IP address is correct for the OCS node. Issue the TSO/E command PING using the IP address or OCS node name to verify the connection. If the cause of the failure cannot be determined, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Module

BPXBOTBD

Source

z/OS UNIX System Services kernel (BPX)

Routing Code

1

Descriptor Code

11