Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
BPXB002E z/OS MVS System Messages, Vol 3 (ASB-BPX) SA38-0670-00 |
|
BPXB002E OCS REQUIRES TCP/IP TO BE ACTIVE. START TCP/IP OR HAVE THE
SYSTEM ADMINISTRATOR UNCONFIGURE THE OCS NODES. ExplanationOutboard Communication Server (OCS) received an indication that TCP/IP is not active. TCP/IP is required for OCS to operate. System actionOCS waits for TCP/IP to become active. There may be up to a two-minute delay between TCP/IP activation and OCS node connection. Operator responseEither start TCP/IP or have the system administrator shut down OCS by issuing the ocsconfig command to unconfigure all OCS nodes. If TCP/IP is active, notify the system programmer. System programmer responseVerify that the TSO/E command OBEYFILE was issued to cause TCP/IP to read the TCP/IP profile dataset. Verify that the IP address is correct for the OCS node. Issue the TSO/E command PING using the IP address or OCS node name to verify the connection. If the cause of the failure cannot be determined, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center. ModuleBPXBOTBD Sourcez/OS UNIX System Services kernel (BPX) Routing Code1 Descriptor Code11 |
Copyright IBM Corporation 1990, 2014
|