z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ATR158I

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

ATR158I
RRS INITIALIZATION IS UNABLE TO PROCEED. THE lstype LOGSTREAM lsname HAS A MAXIMUM BUFFER SIZE OF actualmaxbufsize WHICH IS NOT EQUAL TO THE MAXIMUM BUFFER SIZE OF requiredmaxbufsize FOR THE MAIN UR LOGSTREAM mainlsname.

Explanation

When connecting to log stream lsname, RRS detected that the actual maximum buffer size, actualmaxbufsize, for the log stream was not equal to the maximum buffer size, requiredmaxbufsize, for the MAIN UR log stream, mainlsname. To support the log block size that could be written into the log stream, the actual maximum buffer size must be at least as large as the required maximum buffer size for the MAIN UR log stream.

In the message text:
lstype
One of the following:
DELAYED UR
DELAYED UR log stream.
RESTART
RESTART log stream.
lsname
name of the log stream in error.
actualmaxbufsize
maximum buffer size of the log stream in error
requiredmaxbufsize
maximum buffer size of the RRS MAIN UR log stream.
mainlsname
name of the RRS MAIN UR log stream.

System action

RRS backs out of initialization.

Operator response

Inform your system programmer.

System programmer response

  1. Examine the rules for defining the logging structure for the RRS log stream logstreamname. See z/OS MVS Programming: Resource Recovery.
  2. Change the LOGR policy to ensure that the logging structure for log stream logstreamname meets the requirement. See z/OS MVS Setting Up a Sysplex.
  3. Restart RRS.

Module

ATRAMINI

Source

Resource Recovery Services (RRS)

Routing Code

1,2

Descriptor Code

12

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014