z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ATR130I

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

ATR130I
RRS LOGSTREAM CONNECT HAS FAILED FOR MANDATORY LOGSTREAM logstreamname. RC=return-code, RSN=reason-code

Explanation

RRS initialization has encountered an error connecting to the named log stream, which is required for normal RRS processing.

In the message text:
logstreamname
is the log stream in error.
return-code
is the return code from the IXGCONN macro.
reason-code
is the most recent reason code from the IXGCONN macro.

System action

RRS, which cannot function without this log stream, stops its initialization process. The RRS address space is therefore not available for use.

Operator response

Contact the system programmer for help with solving the problem.

System programmer response

For an explanation of the return and reason codes, see the description of IXGCONN in z/OS MVS Programming: Assembler Services Reference IAR-XCT. Verify that all RRS log streams are defined correctly. If necessary, redefine the log streams correctly and reissue the START command for RRS.

Module

ATRAMINI

Source

Resource recovery services (RRS)

Routing Code

1,2

Descriptor Code

12

Go to the previous page Go to the next page