ARC6085I
ICF CATALOG catalogname SPECIFIED IN THE ALLOCATE LIST WAS NOT SELECTED DURING AGGREGATE BACKUP FOR AGGREGATE GROUP agname

Explanation

ABACKUP processing did not select the specified ICF catalog from the ALLOCATE/ALLOCATEEXCLUDE filtering. The ICF catalog was not specified as a fully qualified data set name in the ALLOCATE list, and was found to be unavailable during processing. There is a catalog entry in the standard search order for the specified ICF catalog, but the actual ICF catalog does not exist on the cataloged volume. The ICF catalog is not backed up.
  • The catalogname is the name of the ICF catalog that was not selected during aggregate backup processing.
  • The agname is the name of the aggregate group being processed.

System action

DFSMShsm processing continues.

Programmer response

This message informs you that an error was intercepted during catalog filtering and the ICF catalog was not selected. Previous messages in the SYSLOG further describe the error. See the explanation of messages IDC3009I RC4 REAS108, IEC331I RC4 REAS38, IEC331I RC4 REAS86, and IEC161I RC4 REAS80.

Source