ARC0378I
TTOC RECORD AND TAPE MEDIA CONTENTS ARE INCONSISTENT ON TAPE VOLUME volser, {TAPE VOLUME CANNOT BE RECYCLED AT THIS TIME | RECYCLE PROCESSING HAS BEEN FORCED, ONLY KNOWN DATA SETS HAVE BEEN PROCESSED | TAPE VOLUME CANNOT BE DELETED, VALID DATA SETS MAY EXIST ON THE VOLUME | REUSE CAPACITY, VALID BLOCKS, PCT VALID, AND NUM REC DO NOT CONTAIN VALUES CONSISTENT WITH THE TAPE MEDIA}

Explanation

TAPE VOLUME CANNOT BE RECYCLED AT THIS TIME indicates that a RECYCLE command has failed as a result of a mismatch between the indicated data sets on the tape volume volser as described in the offline control data set record (OCDS) tape table of contents record (TTOC) and the actual data sets residing on the volume.

RECYCLE PROCESSING HAS BEEN FORCED, ONLY KNOWN DATA SETS HAVE BEEN PROCESSED, indicates that a RECYCLE command with FORCE parameter has been allowed to run to completion. This mismatch between indicated data sets on the tape volume volser as described in the OCDS TTOC record and the actual data sets residing on the volume did not prevent recycle processing of known data sets.

TAPE VOLUME CANNOT BE DELETED, VALID DATA SETS MAY EXIST ON THE VOLUME, indicates a DELVOL command has failed as a result of a mismatch between the indicated data sets on the tape volume volser as described in the OCDS TTOC record and the actual data sets residing on the volume. This message is followed by an ARC0260I message.

REUSE CAPACITY, VALID BLOCKS, PCT VALID, AND NUM REC DO NOT CONTAIN VALUES CONSISTENT WITH THE TAPE MEDIA, indicates that a LIST TAPETABLEOFCONTENTS command has been issued and a mismatch between the indicated data sets on the tape volume volser as described in the OCDS TTOC record and the actual data sets residing on the volume has been found.

Without any message insert an error or a system outage has occurred while DFSMShsm has attempted to copy data sets to the tape volume volser. The result is a mismatch between the indicated data sets on the tape volume as described in the OCDS TTOC record and the actual data sets residing on the volume.

System action

DFSMShsm will not select the tape volume volser for output processing until after the mismatch is resolved (see programmer response). DFSMShsm processing continues.

Programmer response

The extended AUDIT MEDIACONTROLS function is used to resolve the missing TTOC data set entries for the tape volume volser, except when RECYCLE processing has been forced. For information about extended AUDIT MEDIACONTROLS and RECYCLE FORCE commands, see the z/OS DFSMShsm Storage Administration.

See the z/OS DFSMShsm Storage Administration for the procedure that documents how to handle inconsistencies between tape media contents and OCDS TTOC records.

Source

DFSMShsm