AHL110A
INVALID EVENT KEYWORD SPECIFIED

Explanation

For the generalized trace facility (GTF), a response to message AHL101A or AHL102A, or a control statement in the GTF parmlib member, specified an incorrect event keyword.

System action

GTF ignores all options on the line in the response or control statement that contains the error. The system continues processing, but GTF initialization does not continue until the error is corrected. If the error occurred in the GTF parmlib member, the system issues message AHL124I to identify the error source.

Operator response

In your reply to this message, correct the event keyword and enter all options on the line again. If the error is in the GTF parmlib member, notify the system programmer.

System programmer response

If a GTF control statement caused the error, supply the correct keyword in the GTF parmlib member and restart GTF.

Module

AHLTPMT

Module

Generalized trace facility (GTF)