ADR024E
(ttt)-mmmmm(yy), TRACKS/OUTTRACKS VALUE IS INVALID FOR DEVICE. VALID CYLINDER RANGE IS 0 TO X'ccccccc'. VALID TRACK RANGE IS 0 TO X'h'

Explanation

The following values are not valid for the specified device types: (1) the range specified in the TRACKS keyword of a DUMP, COPY, RESTORE, or PRINT, or (2) the range specified for the OUTTRACKS keyword for COPY or RESTORE. The TRACKS values must fall within the cylinder and track range indicated in the message. The cccc and hhhh are high cylinder and head numbers, respectively, in decimal notation.

System action

The task ends. Processing continues with the next control statement. The return code is 8.

Operator response

None.

Programmer response

Correct the error, and rerun the job.

Source

DFSMSdss