ADR287I
(ttt)-mmmmm(yy), FCWITHDRAW WAS ISSUED FOR VOLUME volume_serial_number ON UNIT device_number BUT THE VOLUME WAS NOT INITIALIZED, RETURN CODE return_code

Explanation

Following a successful DUMP operation, DFSMSdss attempted to invoke ICKDSF to initialize the source volume of the DUMP operation because the FCWITHDRAW keyword was specified. However, an FCWITHDRAW was still issued against the volume as requested. The return codes below explain the reason why the volume was not initialized:
1
The VTOC tracks on the source volume of the DUMP operation are not the target of a FlashCopy® relationship.
2
TRACKS was specified but the tracks range specified did not designate range that represents the entire volume.
3
The volume is a VM-format volume (CP volume).
4
The volume does not support FlashCopy Version 2.
5
Patch byte at offset X'4D' in ADRPATCH contains a nonzero value that indicates bypassing volume initialization.
6
ICKDSF failed to initialize the volume.

Operator response

None.

Programmer response

The contents of the volume are possibly invalid. Determine whether the volume is usable and initialize the volume with ICKDSF if necessary.

Source