z/OS MVS Programming: Sysplex Services Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Loss of Connectivity Before a System-Managed Process Is Initiated

z/OS MVS Programming: Sysplex Services Guide
SA23-1400-00

System-managed rebuild and duplexing rebuild will not be initiated if, at the time of the start request, any active or terminating connector has lost connectivity to the target structure. (A terminating connector is one that has disconnected but whose peer connectors have not yet responded to the Disconnect event.)

Neither system-managed rebuild nor system-managed duplexing rebuild will be initiated in response to a loss of connectivity. An IXLREBLD request to start a system-managed process cannot specify STARTREASON=LOSSCONN, and the specification of REBUILDPERCENT in the CFRM policy is ignored.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014