Installing SMCS

z/OS MVS Planning: Operations
SA23-1390-00

An SMCS console can be a real 3270 type device, but usually it will be a 3270 emulator such as IBM® Personal Communications. SMCS supports VTAM® LU Type 0 or Type 2, and SMCS consoles must support Extended Data Stream and the Read Partition Query function.

Installing SMCS consoles requires some VTAM Definitions:
  • Define the SMCS application.
  • Create a LOGON mode table (optional).
  • Indicate that certain LUs are always to be used for SMCS (optional).
CONSOLxx also requires some changes:
  • Specify that the SMCS application is to be started.
  • Define some SMCS consoles.
Finally, RACF® requires some definitions:
  • Userids for operators.
  • Command authority.