RMF XP Product Section

Offsets Name Length Format Description
0 0 SMF104MFV 2 packed RMF™ version number.
2 2 SMF104PRD 8 EBCDIC Product name (RMF XP).
10 A SMF104IST 4 packed Time that the RMF XP measurement interval started, in the form 0hhmmssF, where hh is the hours, mm is the minutes, ss is the seconds, and F is the sign.
14 E SMF104DAT 4 packed Date when the RMF measurement interval started, in the form 0cyydddF. See Standard SMF record header for a detailed description.
18 12 SMF104INT 4 packed Duration of RMF measurement interval, in the form mmsstttF, where mm is the minutes, ss is the seconds, ttt is the milliseconds, and F is the sign. The end of the measurement interval is the sum of the recorded start time and this field.
22 16 SMF104LGO 8 binary Offset GMT to local time (STCK format).
30 1E   2   Reserved.
32 20 SMF104XPL 2 binary RMF XP functionality level.
34 22 SMF104CPX 24 EBCDIC System complex name, specified with the COMPLEX parameter in the cfg4A|X|Z|W configuration file.
58 3A SMF104OSL 8 EBCDIC Operating system label served by RMF XP (AIX®, LINUX or WINDOWS).
66 42 SMF104PLT 2 binary Platform type served by RMF XP:
0
System p®
1
System x®
2
z Systems
68 44 SMF104MVS 8 EBCDIC z/OS® software level for the current system (consists of an acronym and the version, release, and modification level - ZVvvrrmm).
76 4C SMF104XNM 8 EBCDIC Sysplex name of the current sysplex as defined in parmlib member COUPLExx.
84 54 SMF104SNM 8 EBCDIC System name for the current system as defined in parmlib member IEASYSxx SYSNAME parameter.