This section contains one control section followed by a data set section for each data set in the report.
Offsets | Name | Length | Format | Description | |
---|---|---|---|---|---|
0 | 0 | R79BETYP | 1 | EBCDIC | Type of data that follows: P — PAGE data sets |
1 | 1 | 3 | Reserved. | ||
PGSP Data Set Section: | |||||
0 | 0 | R79BSALC | 4 | binary | Number of slots/sets in this data set. |
4 | 4 | R79BSAVL | 4 | binary | Number of slots/sets available. |
8 | 8 | R79BSLBD | 4 | binary | Number of bad slots/sets. |
12 | C | R79BSUSE | 4 | binary | Number of samples that indicate ASM is using the data set. |
16 | 10 | R79BSIOS | 4 | binary | Number of SSCH instructions issued for the data set. |
20 | 14 | R79BREQS | 4 | binary | Number of pages transferred to/from the data set. |
24 | 18 | R79BFLG | 1 | binary | Flags
|
25 | 19 | R79BDEV | 1 | binary | Device type. |
26 | 1A | R79BDADR | 3 | EBCDIC | Device number or 'UCB' for 4-digit device numbers. |
29 | 1D | R79BVSER | 6 | EBCDIC | Volume serial number. |
35 | 23 | R79BDSN | 44 | EBCDIC | Data set name. |
79 | 4F | R79BFL2 | 1 | binary | Flags
|
80 | 50 | R79BDEVN | 8 | EBCDIC | Device name (blank if device name cannot be determined). |
88 | 58 | R79BCU | 8 | EBCDIC | Control unit name (blank if control unit name cannot be determined). |
96 | 60 | R79BDVN | 2 | binary | Device number (binary). |