Device Data Section

There is one section per device.

Offsets Name Length Format Description
0 0 SMF74NUM 2 binary Device number, in the range X'0000' to X'FFFF'.
2 2 SMF74LCU 2 binary Logical control unit number, in the range X'0000' to X'FFFF'.
4 4   1   Reserved.
5 5 SMF74CNF 1 binary Device indicator
Bit
Meaning when set
0
IOS queue length is incorrect
1
No logical control unit information
2
Data contained in fields SMF74SSC through SMF74DIS is incorrect
3
Device has been deleted
4
Only partial statistics are available
5
Reserved.
6
Data recorded is incorrect because device was configured during interval
7
Device is currently online.
6 6 SMF74SER 6 EBCDIC Volume serial of the volume mounted on this device (tape or direct access device only).
12 C SMF74TYP 4 binary Unit type.
16 10 SMF74NUX 4 binary Number of unit control blocks (UCBs) for a parallel access volume. For HyperPAV base devices (bit 6 of SMF74CNX is set), this is the accumulated number of HyperPAV aliases.
20 14 SMF74SSC 4 binary Start subchannel count. This is the number of physical requests to the device and includes SSCH and RSSCH instructions.
24 18 SMF74MEC 4 binary Measurement event count (number of SSCH instructions for which connect, pending, and active times were stored).
28 1C SMF74CNN 4 binary Device connect time (in 128-microsecond units).
32 20 SMF74PEN 4 binary Device pending time (in 128-microsecond units).
36 24 SMF74ATV 4 binary Device active time (in 128-microsecond units).
40 28 SMF74DIS 4 binary Device disconnect time (in 128-microsecond units).
44 2C SMF74QUE 4 binary Number of requests queued in IOS for this device.
48 30 SMF74UTL 4 binary Number of samples when the device was reserved but an SSCH instruction had not been issued to the device.
52 34 SMF74RSV 4 binary Number of samples taken when the device was reserved.
56 38   4   Reserved.
60 3C SMF74ALC 4 binary Number of samples taken that indicated that the device was allocated.
64 40 SMF74MTP 4 binary Number of samples taken that indicated a mount pending condition.
68 44 SMF74NRD 4 binary Number of samples taken that indicated that the device was not ready.
72 48 SMF74COF 2 binary Number of requests that had hardware timer overflow for connect time measurement.
74 4A SMF74ICT 2 binary Number of incorrect samples.
76 4C SMF74DVB 4 binary Device busy delay time, from subchannel information block (SCHIB) (in 128-microsecond units).
80 50   4   Reserved.
84 54 SMF74CLF 1 binary DASD report control flag
Bit
Meaning when set
0
Number option active indicator
1
Storage group option active indicator
2
Storage group name changed during the interval
3
Mount pending condition exists at the start of the interval
4
Mount pending condition exists at end of the interval
5
Reserved
6
CTC with special protocol
7
Reserved.
85 55   3   Reserved.
88 58 SMF74SGN 8 EBCDIC Storage group name as defined by DFSMS.
96 60 SMF74NDA 4 binary Total number of allocations in effect for the device.
100 64 SMF74DEV 8 EBCDIC Device model name. This field is blank if device name cannot be determined.
108 6C SMF74CU 8 EBCDIC Control unit name. Blank if control unit name cannot be determined.
116 74   4   Reserved.
120 78 SMF74CNX 1 binary Device flag extensions:
Bit
Meaning when set
0
Device dynamically changed
1
Device disconnect time is not valid
2
Base exposure of a parallel access volume
3
Number of alias exposures has changed
4
Timing facility not active
5
Device connect time is invalid
6
HyperPAV base device
7
Device connected to FICON®.
121 79   1   Reserved.
122 7A SMF74MTC 2 binary Number of tape mounts detected against the device during the interval.
124 7C SMF74DTS 1 binary Shared Device report control flag
Bit
Meaning when set
0
Valid node descriptor ID retrieved
1
No valid node descriptor ID retrieved
2
Reserved
3
SMF74SHR is valid
4
Device is shared/assigned to multiple systems
5–7
Reserved.
125 7D SMF74DCT 28 EBCDIC Node descriptor ID for selfdescribing devices (if bit 0 of SMF74SRD on).

4-byte device number in EBCDIC format left justified with trailing blanks (if bit 1 of SMF74DTS is on).

153 99 SMF74HPC 1 binary Number of HyperPAV aliases configured for that LSS.
154 9A SMF74NSS 2 binary Number of skipped samples caused by too large delta values.
156 9C SMF74PSM 4 binary Number of successful PAV samples.
160 A0 SMF74PCT 4 binary Number of unsuccessful PAV counts.
164 A4 SMF74CMR 4 binary Command response time in units of 128 microseconds.
168 A8 SMF74CAP 4 binary DASD volume capacity (specified by the number of available cylinders).
Start of change172End of change Start of changeACEnd of change Start of changeSMF74IDTEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeInterrupt delay time in units of 128 microseconds. This field is zero if not supported by the hardware.End of change
176 B0 SMF74CUQ 4 binary Control Unit Queuing Time.
180 B4   1   Reserved.
181 B5 SMF74SCS 1 binary Subchannel set ID.
182 B6 SMF74NM2 2 binary Device number (same as SMF74NUM).