IXGRPT1 flags the existence of events that affect the interpretation of system logger data
for capacity planning. Some events apply to coupling facility based log streams only, while
others apply to both coupling facility and dasd only log streams.
Coupling facility log stream only events include:
- For every interval, IXGRPT1 displays the number of STRUCTURE FULL events
that were detected for a coupling facility log stream. Frequent STRUCTURE FULL events
can indicate a poorly sized coupling facility or that the applications writing
to the coupling facility log stream have sporadic bursts of high activity. The installation
should perform additional analysis.
- For every interval, IXGRPT1 displays the number of STRUCTURE REBUILD events
that occur. Frequent STRUCTURE REBUILD events indicate a need for further
analysis.
Coupling facility and
dasd only log stream events include: