IBM® places the following
defaults in IEAABD00:
SDATA=(LSQA,CB,ENQ,TRT,ERR,DM,IO,SUM),
PDATA=(PSW,REGS,SPLS,ALLPA,SA)
These options request a dump of the following areas:
- LSQA, including subpools 229, 230, and 249
- formatted control blocks for the task
- formatted global resource serialization control blocks for the
task
- GTF trace and/or system trace
- recovery termination control blocks for the task
- data management control blocks for the task
- IOS control blocks for the task
- summary data (see explanation under SUM parameter)
- PSW at entry to ABEND
- contents of general registers at entry to ABEND
- save area linkage information and a backward trace of save areas
- modules listed on the link pack area queue for the task and the
job pack area queue for the task, and active SVC modules related to
the failing task
- user storage allocated for the task.