LOAD - Execute form

The execute form of the LOAD macro can refer to and modify the parameter list constructed by the list form of the macro.

Syntax

The execute form of the LOAD macro is written as follows:

Syntax Description
   
   name name: Symbol. Begin name in column 1.
   
One or more blanks must precede LOAD.
   
LOAD  
   
One or more blanks must follow LOAD.
   
EP=entry name entry name: Symbol.
EPLOC=entry name addr entry name addr: RX-type address, or register (2) - (12).
DE=list entry addr list entry addr: RX-type address, or register (2) - (12).
   
   ,DCB=dcb addr dcb addr: RX-type address, or register (2) - (12).
   
   ,ERRET=err rtn addr err rtn addr: RX-type address, or register (2) - (12).
   
   ,LSEARCH=NO Default: No
   ,LSEARCH=YES  
   
   ,LOADPT=addr addr: RX-type address or register (2) - (12).
   
   ,EXTINFO=addr addr: A-type address.
   
   ,RELATED=value  
   
,SF=(E,list addr) list addr: RX-type address or register (2) - (12) or (15).
   

Parameters

The parameters are explained under the standard form of the LOAD macro with the following exception:

,SF=(E,list addr)
Specifies the execute form of the LOAD macro.