Server specifications provide detailed information for
your server, including dimensions, electrical, power, temperature,
environment, and service clearances.
Use the following specifications to plan for your server.
The
7116 expansion unit is available with model 9406-800 or 9406-810.
The
7116 expansion unit requires a power cord.
Dimensions are shown
for model 9406-800 or 9406-810 only.
Table 1. Dimensions Measurements |
9406-800 and 9406-810 Width |
9406-800 and 9406-810 with
7116 Width |
9406-800 and 9406-810 Depth |
9406-800 and 9406-810 Height |
Height in 0551 rack2,
4 |
Metric |
366 mm |
552 mm |
610 mm |
610 mm |
16 EIA |
English |
14.5 in. |
21.9 in. |
24 in. |
24 in. |
16 U |
Table 2. Maximum configuration
weightModel 9406-800 and 9406-810 |
Model 9406-800 and 9406-810
with 7116 |
52.7 kg (116 lb) |
79.6 kg (175 lb) |
Table 3. ElectricalPower factor |
0.95 |
|
Model 9406-800 and
9406-810 |
7116 expansion unit |
Inrush current |
41 A |
Maximum kVA (each has its own power
cord) |
0.421 |
0.368 |
Leakage current (maximum) |
3.5 mA |
Rated voltage and frequency5 |
100-127/200-240 V ac at 50-60
plus or minus 0.5 Hz |
100-127/200-240 V ac at 50-60 plus or minus
0.5 Hz |
Phase |
1 |
Thermal output (maximum) |
1365 Btu/hr |
1194 Btu/hr |
Power requirements maximum (watts) |
|
|
400 |
350 |
Table 4. Temperature requirementsOperating |
Nonoperating |
10 - 38°C (50 - 100.4°F) |
1 - 60°C (33.8 - 140°F) |
Table 5. Environment requirements Environment |
Operating |
Nonoperating |
Noncondensing humidity
|
8 - 80% |
8 - 80% |
Wet bulb temperature |
23°C (73.4 - °F) |
27°C (80.6°F) |
Maximum altitude |
3048 m (10000 ft) |
|
Table 6. Noise emissions1 Property |
Operating |
Idle |
LWAd (Category 2E, General business)
9406-800 or 9406-810 only |
5.9 bels |
5.8 bels |
LWAd (Category 2E, General business)
9406-800 or 9406-810 with 7116 |
6.3 bels |
6.1 bels |
LpAm (1-meter bystander) 9406-800
or 9406-810 only |
41 dB |
40 dB |
LpAm (1-meter bystander) 9406-800
or 9406-810 with 7116 |
45 dB |
43 dB |
Table 7. Service clearancesFront |
Back |
Sides3 |
Top3 |
762 mm |
1219 mm |
762 mm |
762 mm |
30 in. |
48 in. |
30 in. |
30 in. |
Table 8. NotesNotes: - For a description of noise emission values, see Acoustics.
- Feature code 0133 is manufacturing installed in a rack. Feature
code 0137 is field installed in a rack.
- Side and top clearances are optional when operating.
- See 0551 rack configurations for typical configurations
when the 0551 rack is populated with various server models.
- The power supplies automatically accept any voltage with the published
rated voltage range. If dual power supplies are installed and operating,
the power supplies draw approximately equal current from the utility
(mains) and provide approximately equal current to the load.
|
Delivery
and subsequent transportation of the equipment
DANGER
Heavy equipment—personal injury or equipment
damage might result if mishandled. (D006)
You must
prepare your environment to accept the new product based on the installation
planning information provided, with assistance from an IBM® Installation Planning Representative
(IPR) or IBM authorized
service provider. In anticipation of the equipment delivery, prepare
the final installation site in advance so that professional movers
or riggers can transport the equipment to the final installation site
within the computer room. If for some reason, this is not possible
at the time of delivery, you must make arrangements to have professional
movers or riggers return to finish the transportation at a later date.
Only professional movers or riggers should transport the equipment.
The IBM authorized
service provider can only perform minimal frame repositioning within
the computer room, as needed, to perform required service actions.
You are also responsible for using professional movers or riggers
when you relocate or dispose of equipment.