LICIP14

Licensed Internal Code detected a card slot test failure.

For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.

  1. Has the I/O adapter moved to a new card location?
    • Yes: Continue with the next step.
    • No: Go to step 4.
  2. Perform one of the following, and then continue with the next step:
    • Use the concurrent maintenance option in Hardware Service Manager in SST/DST to power off, remove, reinsert, and power on the I/O adapter.
    • Power off the system, remove and reinsert the I/O adapter. Then IPL the system.
  3. Does the reference code occur again for this same I/O adapter?
    • Yes: Continue with the next step.
    • No: No further service action is needed.

      This ends the procedure.

  4. Move the I/O adapter to a different card location by performing one of the following, and then continue with the next step:
    • Use the concurrent maintenance option in Hardware Service Manager in SST/DST to power off, remove the I/O adapter, install the I/O adapter in a different card location, and power on the I/O adapter.
    • Power off the system, remove the I/O adapter, install the I/O adapter in a different card location, and then IPL the system.
  5. Does the same reference code occur again for this I/O adapter?
    • Yes: Replace the I/O adapter.

      This ends the procedure.

    • No: Replace the backplane.

      This ends the procedure.