Error event IDs and error codes

Error codes describe a service procedure that must be followed. Each event ID that requires service has an associated error code.

Note: Service procedures that involve field-replaceable units (FRUs) do not apply to software-based products, such as IBM Spectrum Virtualize™.For information about possible user actions that relate to FRU replacements, refer to your hardware manufacturer's documentation.

Error codes can be either notification type E (error) or notification type W (warning). Table 1 lists the event IDs that have corresponding error codes, and shows the error code, the notification type, and the condition for each event. For a list of informational events, which do not have associated error codes, see Informational events.

The 07nnnn event ID range refers to node errors that were logged by the system. The last 3 digits represent the error that was reported by the node. You can find these codes in the list of error codes at the end of this topic.

Table 1. Error event IDs and error codes
Event ID Notification type Condition Error code
009020 E A system recovery has run. All configuration commands are blocked. 1001
009040 E The error event log is full. 1002
009052 W The following causes are possible:
  • The node is missing.
  • The node is no longer a functional member of the system.
1196
009053 E A node has been missing for 30 minutes. 1195
009054 W Node has been shut down. 1707
009100 W The software install process has failed. 2010
009101 W Software install package cannot be delivered to all nodes. 2010
009110   Software install process stalled due to lack of redundancy 2010
009115   Software downgrade process stalled due to lack of redundancy 2008
009150 W Unable to connect to the SMTP (email) server. 2600
009151 W Unable to send mail through the SMTP (email) server. 2601
009170 W Remote Copy feature capacity is not set. 3030
009171 W The FlashCopy® feature capacity is not set. 3031
009172 W The Virtualization feature has exceeded the amount that is licensed. 3032
009173 W The FlashCopy feature has exceeded the amount that is licensed. 3032
009174 W Remote Copy feature license limit exceeded. 3032
009175 W Thin-provisioned volume usage not licensed. 3033
009176 W The value set for the virtualization feature capacity is not valid. 3029
009177 E A physical disk FlashCopy feature license is required. 3035
009178 E A physical disk Metro Mirror and Global Mirror feature license is required. 3036
009179 E A virtualization feature license is required. 3025
009180 E Automatic recovery of offline node failed. 1194
009181 W Unable to send email to any of the configured email servers. 3081
009182 W The external virtualization feature license limit was exceeded. 3032
009183 W Unable to connect to LDAP server. 2251
009184 W The LDAP configuration is not valid. 2250
009185 E The limit for the compression feature license was exceeded. 3032
009186 E The limit for the compression feature license was exceeded. 3032
009187 E Unable to connect to LDAP server that has been automatically configured. 2256
009188 E Invalid LDAP configuration for automatically configured server. 2255
009189 W A licensable feature's trial-timer has reached 0. The feature has now been deactivated. 3082
009190 W A trial of a licensable feature will expire in 5 days. 3083
009191 W A trial of a licensable feature will expire in 10 days. 3084
009192 W A trial of a licensable feature will expire in 15 days. 3085
009193 W A trial of a licensable feature will expire in 45 days. 3086
009194 W Easy Tier feature license limit exceeded. 3032
009195 W FlashCopy feature license limit exceeded. 3032
009196 W External virtualization feature license limit exceeded. 3032
009197 W Remote copy feature license limit exceeded. 3032
009198 W System update completion is required. 2050
009199 W System update completion has stalled. 2012
009200 W Encryption feature license limit exceeded 3032
009201 W The quorum application is out of date and needs to be redeployed. 3123
009202 W System SSL certificate will expire within the next 30 days. 3130
009203 W System SSL certificate has expired. 2258
009205 W No active quorum device found on this cluster. 3124
010002 E The node ran out of base event sources. As a result, the node has stopped and exited the system. 2030
010003 W The number of device logins has reduced. 1630
010004 W Device excluded due to excessive errors on all Managed Disks 1640
010006 E Access beyond end of disk, or Managed Disk missing. 2030
010008 E The block size is invalid, the capacity or LUN identity has changed during the managed disk initialization. 1660
010010 E The managed disk is excluded because of excessive errors. 1310
010011 E The remote port is excluded for a managed disk and node. 1220
010012 E The local port is excluded. 1210
010013 E The login is excluded. 1230
010015 E Timeout due to non-responsive device 1340
010016 E Timeout due to lost command 1340
010017 E A timeout has occurred as a result of excessive processing time. 1340
010018 E An error recovery procedure has occurred. 1370
010019 E A managed disk is reporting excessive errors. 1310
010020 E The managed disk error count threshold has exceeded. 1310
010021 W There are too many devices presented to the system. 1200
010022 W There are too many managed disks presented to the system. 1200
010023 W There are too many LUNs presented to a node. 1200
010024 W There are too many drives presented to a system. 1200
010025 W A disk I/O medium error has occurred. 1320
010026 W A suitable MDisk or drive for use as a quorum disk was not found. 1330
010027 W The quorum disk is not available. 1335
010028 W A controller configuration is not supported. 1625
010029 E A login transport fault has occurred. 1360
010030 E A managed disk error recovery procedure (ERP) has occurred. The node or controller reported the following:
  • Sense
  • Key
  • Code
  • Qualifier
1370
010031 E One or more MDisks on a controller are degraded. 1623
010032 W The controller configuration limits failover. 1625
010033 E The controller configuration uses the RDAC mode; this is not supported. 1624
010034 W Persistent unsupported controller configuration. 1695
010035 W Controller has quorum disabled, but quorum disk is configured 1570
010040 E The controller system device is only connected to the node through a single initiator port. 1627
010041 E The controller system device is only connected to the node through a single target port. 1627
010042 E The controller system device is only connected to the nodes through a single target port. 1627
010043 E The controller system device is only connected to the nodes through half of the expected target ports. 1627
010044 E The controller system device has disconnected all target ports to the nodes. 1627
010045 W Number of Device paths from the controller site allowed accessible nodes has reduced 1630
010051   A Solid state drive is missing from the configuration 1202
010055 W An unrecognized SAS device. 1665
010056 E SAS error counts exceeded the warning thresholds. 1216
010057 E SAS errors exceeded critical thresholds. 1216
010066 W Controller indicates that it does not support descriptor sense for LUNs that are greater than 2 TBs. 1625
010067 W Too many enclosures were presented to a system. 1200
010070 W Too many controller target ports were presented to the system. 1200
010071 W Too many target ports were presented to the system from a single controller. 1200
010098 W There are too many drives presented to a system. 1200
010100 W Incorrect connection detected to a port. 1669
010101 E Too many long IOs to drive. 1680
010102 E A drive is reported as continuously slow with contributory factors. 1680
010103 E Too many long IOs to drive (Mercury drives). 1680
010104 E A drive is reported as continuously slow with contributory factors (Mercury drives). 1680
010105 W Storage system connected to unsupported port 2080
010106 E Drive reporting too many t10dif errors. 1680
010107 W Encrypting MDisk is no longer encrypted 2580
010110 W Drive firmware download canceled because of system changes. 3090
010111 W Drive firmware download canceled because of a drive download problem. 3090
010117 W A disk controller is not accessible from a node allowed to access the device by site policy 1627
010118 W Too many drives attached to the system. 1179
010119 W Drive data integrity error. 1322
010120 W A member drive has been forced to turn off protection information support. 2035
010121 E Drive exchange required. 1693
010123 W Performance of external MDisk has changed. 2115
010124 W iSCSI session excluded. 1230
010125 W A Flash drive is expected to fail within six months due to limited write endurance. 1215
010126 W A Flash drive with high write endurance usage rate. 2560
020001 E There are too many medium errors on the MDisk. 1610
020002 E A storage pool is offline. 1620
020003 W There are insufficient virtual extents. 2030
020008 E Storage optimization services disabled. 3023
029001 E The MDisk has bad blocks. 1840
029002 W The system failed to create a bad block because MDisk already has the maximum number of allowed bad blocks. 1226
029003 W The system failed to create a bad block because the system already has the maximum number of allowed bad blocks. 1225
030000 W FlashCopy prepare failed due to cache flush failure. 1900
030010 W FlashCopy has been stopped due to the error indicated in the data. 1910
030020 W Unrecovered FlashCopy mappings. 1895
045102 W SAS cable is not working at full capacity 1260
045103 E An attempt to automatically configure a reseated or replaced drive has failed. 1686
045104 W Drives are single ported due to a spare node 3200
045105 E Enclosure secondary expander module has failed 1267
045106 E Enclosure secondary expander module FRU identity is not valid 1266
045107 E Enclosure secondary expander module temperature sensor cannot be read 1267
045108 E Enclosure secondary expander module temperature has passed warning threshold 1098
045109 E Enclosure secondary expander module temperature has passed critical threshold 1095
045110 E Enclosure display panel is not installed 1268
045111 E Enclosure display panel temperature sensor cannot be read 1268
045112 E Enclosure display panel temperature has passed warning threshold 1098
045113 E Enclosure display panel temperature has passed critical threshold 1095
045114 E Enclosure secondary expander module connector excluded due to too many change events 1267
045119 E Enclosure display panel VPD cannot be read 1268
045120 E Enclosure secondary expander module is missing 1267
045121 E Enclosure secondary expander module connector excluded due to dropped frames 1267
045122 E Enclosure secondary expander module connector is excluded and cannot be unexcluded 1267
045123 E Enclosure secondary expander module connectors excluded as the cause of single ported drives 1267
045124 E Enclosure secondary expander module leaf expander connector excluded as the cause of single ported drives 1267
050001 W The Metro Mirror or Global Mirror relationship cannot be recovered. 1700
050002 W A Metro Mirror or Global Mirror relationship or consistency group exists within a system, but its partnership has been deleted. 3080
050010 W A Global Mirror relationship has stopped because of a persistent I/O error. 1920
050011 W A remote copy has stopped because of a persistent I/O error. 1915
050020 W Remote Copy relationship or consistency groups lost synchronization. 1720
050030 W There are too many system partnerships. The number of partnerships has been reduced. 1710
050031 W There are too many system partnerships. The system has been excluded. 1710
050040 W Background copy process for the remote copy was blocked. 1960
050041 W Partner cluster IP address unreachable 2021
050042 W Cannot authenticate with partner cluster. 2022
050043 W Unexpected cluster ID for partner cluster 2023
050050 E The Global Mirror secondary volume is offline. The relationship has pinned hardened write data for this volume. 1925
050060 E The Global Mirror secondary volume is offline due to missing I/O group partner node. The relationship has pinned hardened write data for this volume but the node containing the required data is currently offline. 1730
050070 E Global Mirror performance is likely to be impacted. A large amount of pinned data for the offline volumes has reduced the resource available to the global mirror secondary disks. 1925
050080 W HyperSwap® volume has lost synchronization between sites. 1940
050081 W HyperSwap consistency group has lost synchronization between sites. 1940
050082 E Compression has stopped unexpectedly 3131
060001 W A thin-provisioned volume copy is offline because of insufficient space. 1865
060002 E A thin-provisioned volume copy is offline because of corrupt metadata. 1862
060003 E A thin-provisioned volume copy is offline because of a failed repair. 1860
060004 W A compressed volume copy is offline because of insufficient space. 1865
060005 E A compressed volume copy is offline because of corrupt metadata. 1862
060006 E A compressed volume copy is offline because of a failed repair. 1860
060007 E A compressed volume copy has bad blocks. 1850
060008 W Data reduction pool meta data corrupt 1862
060009 W Pool's virtual disk copies offline due to failed data reduction pool repair 1860
060010 W Virtual Disk Copies offline due to insufficient space in Data Reduction Pool 1865
062001 W System is unable to mirror medium error. 1950
062002 E Mirrored volume is offline because it cannot synchronize data. 1870
062003 W Repair of a mirrored volume stopped because of difference. 1600
064001 W A host port has more than four logins to a node 2016
070000 E Unrecognized node error. 1083
070510 E Detected memory size does not match the expected memory size. 1022
070511 E DIMMs are incorrectly installed. 1009
070517 E The WWNN that is stored on the service controller and the WWNN that is stored on the drive do not match. 1192
070521 E Unable to detect any Fibre Channel adapter. 1016
070522 E The system board processor has failed. 1020
070523 E The internal disk file system of the node is damaged. 1187
070524 E Unable to update BIOS settings. 1027
070525 E Unable to update the service processor firmware for the system board. 1020
070528 E The ambient temperature is too high while the system is starting. 1182
070534 E System board fault 1026
070536 E A system board device breached critical temperature threshold. 1084
070538 E A PCI Riser breached critical temperature threshold. 1085
070541 E Multiple hardware failures 1184
070542 E A processor has failed. 1024
070543 E No usable persistent data could be found on the boot drives. 1035
070544 E The boot drives do not belong in this node. 1035
070545 E Boot drive and system board mismatch. 1035
070547 E Pluggable TPM is missing or broken 1051
070548 E The node has compression hardware configured but no compression hardware is available. 1046
070549 E The node's compression hardware has failed. 1046
070550 W Cannot form system due to lack of resources. 1192
070551 W Cannot form cluster due to lack of cluster resources, overridequorum possible 1192
070556 E Duplicate WWNN detected on the SAN. 1192
070558 E A node is unable to communicate with other nodes. 1192
070560 E Battery cabling fault. 1108
070561 E Battery backplane or cabling fault. 1109
070562 E The node hardware does not meet minimum requirements. 1183
070564 E Too many software failures. 1188
070565 E The internal drive of the node is failing. 1030
070569 E CPU temperature breached critical threshold. 1093
070572 E Battery protection temporarily unavailable; both batteries are expected to be available soon. 1473
070573 E Node software inconsistent 1192
070574 E The node software is damaged. 1187
070576 E The system data cannot be read. 1030
070578 E The system data was not saved when power was lost. 1194
070579 E Battery subsystem has insufficient charge to save system data. 1107
070580 E Unable to read the service controller ID. 1044
070581 E UPS battery fault 1181
070582 E UPS battery fault 1181
070583 E UPS electronics fault 1171
070584 E UPS output load high 1166
070585 E UPS electronics fault 1171
070586 E UPS AC input power fault 1141
070587 E Incorrect type of uninterruptible power supply detected. 1152
070588 E UPS configuration error 1151
070589 E UPS ambient temperature threshold exceeded 1136
070590 E UPS fault 1186
070670 W Insufficient uninterruptible power supply charge to allow node to start. 1193
070690 W Node held in service state. 1189
070700 W Fibre Channel adapter missing 1045
070701 E Fibre Channel adapter failed 1046
070702 E Fibre Channel adapter PCI error 1046
070703 E Fibre Channel adapter degraded 1046
070704 W Fewer Fibre Channel ports operational. 1060
070705 W Fewer Fibre Channel I/O ports operational. 1450
070706 W Fibre Channel clustered system path failure. 1550
070710 W A high speed SAS adapter is missing 1120
070711 E SAS adapter failed 1046
070712 E SAS adapter PCI error 1046
070713 E SAS adapter degraded 1046
070715 W Fewer SAS ports operational 1046
070717 W SAS ports degraded 1046
070718 W SASA port has unsupported SAS device 1046
070720 W Ethernet adapter missing 1045
070721 E Ethernet adapter failed 1046
070722 E Ethernet adapter PCI error 1046
070723 E Ethernet adapter degraded 1046
070724 W Fewer Ethernet ports 1046
070730   Bus adapter missing 1192
070731   Bus adapter failed 1192
070732   Bus adapter PCI error 1192
070733   Bus adapter degraded 1192
070734   Fewer bus ports operational 1006
070736 E A system board device breached warning temperature threshold. 1084
070737 E A power supply breached temperature threshold. 1212
070738 E A PCI Riser breached warning temperature threshold. 1085
070743 E Boot drive missing or out of sync or failed. 1213
070744 W A boot drive is in the wrong location. 1214
070745 W Boot drive in unsupported slot. 1472
070746 W Technician port connection is not valid. 3024
070747 W Technician connected. 747
070760 E Voltage fault 1110
070761 E Voltage high 1100
070762 E Voltage low 1105
070765 E Fan error 1089
070766 E CMOS battery has failed. 1670
070768 W Ambient temperature warning 1094
070769 W CPU temperature warning 1093
070770 W Shutdown temperature reached 1092
070775 E Power supply has a problem. 1097
070776 W Power supply mains cable is unplugged. 1097
070777 E Power supply is missing. 1097
070779 W Battery is missing. 1129
070780 E Battery has failed. 1130
070810 W Battery is below the minimum operating temperature. 1476
070782 W Battery is above the maximum operating temperature. 1475
070783 E Battery has a communications error. 1109
070784 W Battery is nearing end of life. 1474
070786 E Battery VPD has a checksum error. 1130
070787 E Battery is at a hardware revision level not supported by the current code level. 1473
070830 W Encryption key required 1328
070831 W Encryption key invalid 2555
070832 W Encryption key not found 2555
070833 W USB device (such as hub) unsupported 2555
070836 W Encryption key required 1328
070840 W Detected hardware is not a valid configuration. 1198
070841 W Detected hardware needs activation. 1199
070842 W Fibre Channel IO port mapping failed 1059
070860 W Fibre-channel network fabric is too big. 1800
071500 W Incorrect enclosure 1021
071501 E Incorrect slot 1192
071502 E No enclosure id and cannot get status from partner 1192
071503 E Incorrect enclosure type 1192
071504 E No enclosure id & partner matches 1192
071505 E No enclosure id and partner has cluster data does not match 1192
071506 E No enclosure id and no cluster state on partner 1192
071507 E No enclosure id and no cluster state 1192
071508 W Cluster id different between enclosure and node 1023
071509 E Cannot read enclosure identity 1036
071510 E The detected memory size does not match the expected memory size 1032
071522 E The system board processor has failed. 1034
071523 E Internal disk file system is damaged 1187
071524 E Unable to update BIOS settings 1034
071525 E Unable to update system board service processor firmware 1034
071528 W Ambient temperature too high while system starting 1092
071535 E Canister internal PCIe switch failed 1034
071541 E Multiple hardware failures 1184
071547 E Pluggable TPM is missing or broken 1051
071548 E The node has compression hardware configured but no compression hardware is available. 1046
071549 E The node's compression hardware has failed. 1046
071550 W Cannot form cluster due to lack of cluster resources 1192
071551 W Cannot form cluster due to lack of cluster resources, overridequorum possible 1192
071556 W Duplicate WWNN detected on SAN 1133
071562 E The node's hardware configuration does not meet minimum requirements 1034
071564 W Too many software failures 1188
071565 E The node's internal drive is failing. 1032
071569 E CPU over temp. 1032
071573 E Node software inconsistent 1187
071574 E Node software is damaged 1187
071576 E Cluster state and configuration data cannot be read 1032
071578 E State data was not saved on power loss 1194
071671 W The available battery charge is not enough to allow the node canister to start . Two batteries are charging. 1176
071672 W The available battery charge is not enough to allow the node canister to start . One battery is charging. 1176
071673 E The available battery charge is not enough to allow the node canister to start . No batteries are charging. 1004
071690 W Node held in service state 1189
071700 W Fibre Channel adapter missing 1032
071701 E Fibre Channel adapter failed 1032
071702 E Fibre Channel adapter PCI error 1034
071703 E Fibre Channel adapter degraded 1034
071704 W Fewer Fibre Channel ports operational. 1061
071705 W Fewer Fibre Channel I/O ports operational. 1450
071706 W Fibre Channel clustered system path failure. 1550
071710 W SAS adapter missing 1032
071711 E SAS adapter failed 1032
071712 E SAS adapter PCI error 1034
071713 E SAS adapter degraded 1034
071715 W Fewer SAS ports operational 1034
071717 W SAS ports degraded 1034
071718 W SASA port has unsupported SAS device 1034
071720 W Ethernet adapter missing 1032
071721 E Ethernet adapter failed 1032
071722 E Ethernet adapter PCI error 1034
071723 E Ethernet adapter degraded 1034
071724 W Fewer Ethernet ports 1401
071730 W Bus adapter missing 1032
071731 E Bus adapter failed 1032
071732 E Bus adapter PCI error 1034
071733 E Bus adapter degraded 1034
071734 W Fewer bus ports operational 1006
071747 W Technician connected. 747
071766 E CMOS error 1670
071768 W Ambient temperature warning 1094
071769 W CPU temperature warning 1093
071810 W Battery cold 1156
071782 W Battery hot 1157
071786 E Battery VPD checksum 1154
071830 W Encryption key required 1328
071831 W Encryption key invalid 2555
071832 W Encryption key not found 2555
071833 W USB device (such as hub) unsupported 2555
071836 W Encryption key required 1328
071850 W Canister battery is nearing end of life 1159
072005 E CMOS battery has a failure. 1670
072007 E CMOS battery has a failure. 1670
072008 E CMOS battery has a failure. 1032
072101   System board has more or fewer processors detected. 1025
072102   System board has more or fewer processors detected. 1025
072103   System board has more or lesss processors detected. 1032
072500 W Incorrect enclosure 1021
072501 E Incorrect slot 1192
072502 E No enclosure id and cannot get status from partner 1192
072503 E Incorrect enclosure type 1192
072504 E No enclosure id & partner matches 1192
072505 E No enclosure id and partner has cluster data that does not match 1192
072506 E No enclosure id and no cluster state on partner 1192
072507 E No enclosure id and no cluster state 1192
072508 W Cluster id different between enclosure and node 1023
072509 E Cannot read enclosure identity 1036
072510 E The detected memory size does not match the expected memory size 1032
072522 E The system board processor has failed 1033
072523 E Internal disk file system is damaged 1187
072525 E Unable to update system board service processor firmware 1034
072535 E Canister internal PCIe switch failed 1192
072541 E Multiple hardware failures 1184
072550 W Cannot form cluster due to lack of cluster resources 1192
072551 W Cannot form cluster due to lack of cluster resources, overridequorum possible 1192
072556 E Duplicate WWNN detected on SAN 1133
072562 E The node's hardware configuration does not meet minimum requirements 1034
072564 E Too many software failures 1188
072565 E The node's internal drive is failing. 1032
072569 E CPU over temp. 1032
072573 E Node software inconsistent 1187
072574 E Node software is damaged 1187
072576 E Cluster state and configuration data cannot be read 1032
072578 E State data was not saved on power loss 1194
072650 W The canister battery is not supported. 1149
072651 W The canister battery is missing. 1153
072652 E The canister battery has failed. 1154
072655 E Canister battery communications error 1158
072656 W Canister battery has insufficient charge to support a firehose dump 1197
072690 W Node held in service state 1189
072700 W Fibre Channel adapter missing 1045
072701 E Fibre Channel adapter failed 1046
072702 E Fibre Channel adapter PCI error 1046
072703 E Fibre Channel adapter degraded 1046
072704 W Fewer Fibre Channel ports operational. 1062
072705 W Fewer Fibre Channel I/O ports operational. 1450
072706 W Fibre Channel clustered system path failure. 1550
072710 W SAS adapter missing 1045
072711 E SAS adapter failed 1046
072712 E SAS adapter PCI error 1046
072713 E SAS adapter degraded 1046
072715 W Fewer SAS ports operational 1046
072717 W SAS ports degraded 1046
072718 W SASA port has unsupported SAS device 1046
072720 W Ethernet adapter missing 1045
072721 E Ethernet adapter failed 1046
072722 E Ethernet adapter PCI error 1046
072723 E Ethernet adapter degraded 1046
072724 W Fewer Ethernet ports 1402
072730 W Bus adapter missing 1032
072731 E Bus adapter failed 1032
072732 E Bus adapter PCI error 1032
072733 E Bus adapter degraded 1032
072734 W Fewer bus ports operational 1006
072766 E CMOS error 1670
072840 W A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. 1198
072841 W A supported hardware change was made to this node. User action is required to activate the new hardware. 1199
072850 W Canister battery is nearing end of life 1159
072860 W Fibre-channel network fabric is too big. 1800
073003 W The Fibre Channel ports are not operational. 1060
073004 E Fibre Channel adapter detected PCI bus error. 1012
073005 E System path has a failure. 1550
073006 W The SAN is not correctly zoned. As a result, more than 512 ports on the SAN have logged into one system port. 1800
073251 E More or less Fibre Channel adapters are detected. 1011
073252 E Fibre Channel adapter is faulty. 1055
073258 E Fibre Channel adapter has detected PCI bus error. 1013
073261 E More or less Fibre Channel adapters are detected. 1011
073262 E Fibre Channel adapter is faulty. 1055
073268 E Fibre Channel adapter has detected PCI bus error. 1013
073271 E More or less Fibre Channel adapters are detected. 1011
073272 E Fibre Channel adapter is faulty. 1055
073278 E Fibre Channel adapter has detected PCI bus error. 1013
073305 W Fibre Channel speed has changed. 1065
073310 E Duplicate Fibre Channel frame is detected. 1203
073402 E The Fibre Channel adapter has a failure. 1032
073404 E Fibre Channel adapter has detected PCI bus error. 1032
073500 W Incorrect enclosure 1021
073512 E Enclosure VPD is inconsistent. 1008
073522 E The system board service processor has failed. 1034
073524 E Unable to update BIOS settings 1034
073528 E Ambient temperature is too high during system startup. 1098
073541 E Multiple hardware failures 1184
073551 W Cannot form cluster due to lack of cluster resources, overridequorum possible 1192
073564 W Too many software failures 1188
073569 E CPU over temp. 1032
073576 E Cluster state and configuration data cannot be read 1032
073650 W The canister battery is not supported. 1149
073690 W Node held in service state 1189
073715 W Fewer SAS ports operational 1046
073717 W SAS ports degraded 1046
073718 W SASA port has unsupported SAS device 1669
073766 E CMOS error 1670
073820 W The node canister has detected that it has a hardware type that is not compatible with the control enclosure MTM. 3020
073830 W Encryption key required 1328
073831 W Encryption key invalid 2555
073832 W Encryption key not found 2555
073833 W USB device (such as hub) unsupported 2555
073836 W Encryption key required 1328
073850 W Canister battery is nearing end of life 1159
074001 W System is unable to determine VPD for a FRU. 2040
074002 E The node warm started after a software error. 2030
074003 W A connection to a configured remote system has been lost because of a connectivity problem. 1715
074004 W A connection to a configured remote system has been lost because of too many minor errors. 1716
074500 W Incorrect enclosure 1021
074501 E Incorrect slot 1192
074502 E No enclosure id and cannot get status from partner 1192
074503 E Incorrect enclosure type 1192
074504 E No enclosure id & partner matches 1192
074505 E No enclosure id and partner has cluster data that does not match 1192
074506 E No enclosure id and no cluster state on partner 1192
074507 E No enclosure id and no cluster state 1192
074508 W Cluster id different between enclosure and node 1023
074509 E Cannot read enclosure identity 1043
074510 E The detected memory size does not match the expected memory size 1039
074512 E Enclosure VPD is inconsistent 1029
074521 E Unable to detect any fibre-channel adapter 1192
074522 E The system board processor has failed 1088
074523 E Internal disk file system is damaged 1187
074524 E Unable to update BIOS settings 1034
074525 E Unable to update system board service processor firmware 1192
074528 W Ambient temperature too high while system starting 1087
074534 E System board fault 1039
074535 E Canister internal PCIe switch failed 1034
074536 E A device on the system board is too hot 1192
074538 E PCI Riser too hot 1192
074541 E Multiple hardware failures 1184
074550 W Cannot form cluster due to lack of cluster resources 1192
074551 W Cannot form cluster due to lack of cluster resources, overridequorum possible 1192
074556 W Duplicate WWNN detected on SAN 1133
074562 E The node's hardware configuration does not meet minimum requirements 1034
074564 E Too many software failures 1188
074565 E The node's internal drive is failing. 1039
074569 E CPU over temp. 1192
074573 E Node software inconsistent 1192
074574 E Node software is damaged 1187
074576 E Cluster state and configuration data cannot be read 1039
074578 E State data was not saved on power loss 1194
074650 W The canister battery is not supported. 1192
074651 W The canister battery is missing. 1192
074652 E The canister battery has failed. 1192
074653 W The canister battery is below minimum operating temperature. 1192
074654 W The canister battery is above maximum operating temperature. 1192
074655 E Canister battery communications error 1192
074656 W Canister battery has insufficient charge to support a fire hose dump 1192
074657 E Not enough battery to support graceful shutdown. 1111
074690 W Node held in service state 1189
074710 W SAS adapter missing 1192
074711 E SAS adapter failed 1192
074712 E SAS adapter PCI error 1192
074713 E SAS adapter degraded 1192
074715 W Fewer SAS ports operational 1192
074717 W SAS ports degraded 1192
074718 W SASA port has unsupported SAS device 1192
074720 W Ethernet adapter missing 1039
074721 E Ethernet adapter failed 1039
074722 E Ethernet adapter PCI error 1034
074723 E Ethernet adapter degraded 1034
074724 W Fewer Ethernet ports 1401
074730 W Bus adapter missing 1039
074731 E Bus adapter failed 1039
074732 E Bus adapter PCI error 1034
074733 E Bus adapter degraded 1034
074734 W Fewer bus ports operational 1007
074768 W Ambient temperature warning 1099
074830 W Encryption key required 1328
074831 W Encryption key invalid 2555
074832 W Encryption key not found 2555
074833 W USB device (such as hub) unsupported 2555
074840 W A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. 1198
074841 W A supported hardware change was made to this node. User action is required to activate the new hardware. 1199
075011 E Flash boot device has a failure. 1040
075012 E Flash boot device has recovered. 1040
075015 E Service controller has a read failure. 1044
075021 E Flash boot device has a failure. 1040
075022 E Flash boot device has recovered. 1040
075025 E Service controller has a read failure. 1044
075031 E Flash boot device has a failure. 1040
075032 E Flash boot device has recovered. 1040
075035 E A service controller read failure occurred 1044
076001 E The internal disk for a node has failed. 1030
076002 E The hard disk is full and cannot capture any more output. 2030
076401 E One of the two power supply units in the node has failed. 1096
076402 E One of the two power supply units in the node cannot be detected. 1096
076403 E One of the two power supply units in the node is without power. 1097
076501 E A high-speed SAS adapter is missing. 1120
076502 E The PCIe lanes on a high-speed SAS adapter are degraded. 1121
076503 E A PCI bus error occurred on a high-speed SAS adapter. 1121
076504 E A high-speed SAS adapter requires a PCI bus reset. 1122
076505 E The SAS adapter has an internal fault. 1121
077105 E The node service processor indicated a fan failure. 1089
077106 E The node service processor indicated a fan failure. 1089
077107 E The node service processor indicated a fan failure. 1089
077161 E Node ambient temperature threshold has exceeded. 1094
077162 E The node processor indicated a temperature warning. 1093
077163 E The node service processor or ambient critical temperature threshold has exceeded. 1092
077165 E Node ambient temperature threshold has exceeded. 1094
077166 E Node processor temperature has a warning. 1093
077167 E Node processor or ambient critical temperature threshold has exceeded. 1092
077171 E System board voltage is high. 1101
077172 E System board voltage is high. 1101
077173 E System board voltage is high. 1101
077174 E System board voltage is low. 1106
077175 E System board voltage is low. 1106
077176 E System board voltage is low. 1106
077178 E Power management board has a voltage fault. 1110
077185 E Node ambient temperature threshold has exceeded. 1094
077186 E Temperature warning threshold exceeded 1093
077187 E Temperature critical threshold exceeded 1092
077188 E Power management board voltage has a fault. 1110
078001 E Power domain error. Both nodes in the I/O group are powered by the same UPS. 1155
079500 W The limit on the number of system secure shell (SSH) sessions has been reached. 2500
079501 W Unable to access the Network Time Protocol (NTP) network time server. 2700
079503 W Unable to connect to NTP server that has been automatically configured. 2702
079504 W Hardware configurations of nodes differ in an I/O group. 1470
079505 W Stretch cluster reconfiguration is required to restore a dual site configuration 1178
079506 I Technician port connection is not active. 3024
079507 I Technician port connection is active. 3024
079508 W Performance not optimised for V9000 variants without managed enclosures. 3300
079509 W Performance not optimised for V9000 variants with managed enclosures. 3300
081001 E Ethernet interface has a failure. 1400
082001 E A server error has occurred. 2100
082002 W Service failure has occured. 2100
083001 E System failed to communicate with UPS. 1145
083002 E UPS output loading was unexpectedly high. 1165
083003 E Battery has reached end of life. 1190
083004 E UPS battery has a fault. 1180
083005 E UPS electronics has a fault. 1170
083006 E UPS frame has a fault. 1175
083007 E UPS is overcurrent. 1160
083008 E UPS has a fault but no specific FRU is identified. 1185
083009 E The UPS has detected an input power fault. 1140
083010 E UPS has a cabling error. 1150
083011 E UPS ambient temperature threshold has exceeded. 1135
083012 E UPS ambient temperature is high. 3000
083013 E UPS crossed-cable test is bypassed because of an internal UPS software error. 3010
083101 E System failed to communicate with UPS. 1146
083102 E UPS output loading was unexpectedly high. 1166
083103 E Battery has reached end of life. 1191
083104 E UPS has a battery fault. 1181
083105 E UPS has an electronics fault. 1171
083107 E UPS is overcurrent. 1161
083108 E UPS has a fault but no specific FRU is identified. 1186
083109 E The UPS has detected an input power fault. 1141
083110 E UPS has a cabling error. 1151
083111 E UPS ambient temperature threshold has exceeded. 1136
083112 E UPS ambient temperature is high. 3001
083113 E UPS crossed-cable test is bypassed because of an internal UPS software error. 3011
084000 W An array MDisk has deconfigured members and has lost redundancy. 1689
084050 W An array MDisk is expected to fail within six months due to limited write endurance of member drives 3060
084100 E An array MDisk is corrupt because of lost metadata. 1240
084200 W Array MDisk has taken a spare member that does not match array goals. 1692
084201 W An array has members that are located in a different I/O group. 1688
084300 W An array MDisk is no longer protected by an appropriate number of suitable spares. 1690
084301 W No spare protection exists for one or more array MDisks. 1690
084302 W Distributed array MDisk has fewer rebuild areas available than threshold. 1690
084400 W A background scrub process has found an inconsistency between data and parity on the array. 1691
084420 W Array MDisk has been forced to disable hardware data integrity checking on member drives. 2035
084500 E An array MDisk is offline. The metadata for the inflight writes is on a missing node. 1243
084600 E An array MDisk is offline. Metadata on the missing node contains needed state information. 1243
084700 W Array response time too high. 1750
084701 W Distributed array MDisk member slow write count threshold exceeded. 1750
084800 E Distributed array MDisk offline due to I/O timeout. 1340
085047 W Battery reconditioning required but not possible 1131
085052 E Interface card has degraded PCI link 1039
085055 W External FC data link degraded 1064
085056 W External IB data link degraded 1064
085063 E Canister is missing an interface card 1045
085091 W External iSCSI port not operational 1403
085092 W Too many ISCSI host logins 1803
085118 W System update halted 2010
085160 W Check the air filter 1820
085161 E Array data compromised 1048
085198 W Too many enclosures visible on fabric 1807
085199 W Enclosure visible on fabric managed by another system 1706
085200 W Cabling error. Internal cabling connectivity has changed. 1440
085201 W Enclosure connectivity undetermined. Connectivity to an enclosure can no longer be determined 1440
085202 W Minimal enclosure connectivity not met. 1705
085203 W Config node cannot communicate with canister. 1034
085204 W Managed enclosure is not visible from config node. 1042
085205 W Canister internal error. 1705
085221 I Successful write to USB Flash Drive n/a
085222 W Write failed to USB Flash Drive 1790
086001 E Encryption key unavailable 1739
086002 W Encryption key on USB flash drive removed 2550
086003 W Write to USB Flash Drive failure 1790
086004 I Write to USB Flash Drive successful n/a
086005 W Encryption not committed 1780
086006 E Key Server reported KMIP error 1785
086007 E Key Server reported vendor information error 1785
086008 E Failed to connect to Key Server 1785
086009 W Key Server reported misconfigured primary 1785
087001 E Cloud gateway service restarted 2031
087002 E Cloud gateway service restarted too often 1404
087003 W Cloud account SSL certificate will expire within the next 30 days 3140
087004 W Cloud account not available, cannot resolve hostname 1580
087005 W Cloud account not available, cannot contact cloud provider 2310
087006 W Cloud account not available, cannot communicate with cloud provider 2320
087007 W Cloud account not available, no matching CA certificate 2300
087008 W Cloud account not available, no matching CA certificate 2300
087009 W Cloud account not available, cannot establish secure connection with cloud provider 3100
087010 W Cloud account not available, cannot authenticate with cloud provider 2330
087011 W Cloud account not available, cannot obtain permission to use cloud storage 2330 2305
087012 W Cloud account not available, cannot complete cloud storage operation 3100
087013 W Cloud account not available, cannot access cloud object storage 2105
087014 W Cloud account not available, incompatible object data format 3135
087016 W Cloud account not available, cloud object storage encrypted 1656
087017 W Cloud account not available, cloud object storage not encrypted 1656
087018 W Cloud account not available, cloud object storage encrypted with the wrong key 1657
087019 W No permission to use cloud storage snapshot operation 2305
087020 W Cloud account out of space during cloud storage snapshot operation 2125
087021 W Cannot create container object to cloud object storage during cloud snapshot operation 2305
087022 W A cloud object could not be found during cloud snapshot operation. 3108
087023 W A cloud object was found to be corrupt during cloud snapshot operation. 3108
087024 W A cloud object was found to be corrupt during cloud snapshot decompression operation. 3108
087025 W Etag integrity error during cloud snapshot operation 3108
087026 W Internal Read error during cloud snapshot operation 2120
087027 W Unexpected error occurred, cannot complete cloud snapshot operation 3108
087028 W No permission to use cloud snapshot restore operation 2305
087029 W A cloud object could not be found during a cloud snapshot restore operation 3108
087030 W A cloud object was found to be corrupt during a cloud snapshot restore operation 3108
087031 W A cloud object was found to be corrupt during a cloud snapshot restore decompression operation 3108
087032 W Etag integrity error during cloud snapshot restore operation 3108
087033 W Internal write error during cloud snapshot operation 2120
087034 W Cannot create bad blocks on a managed disk during cloud snapshot restore operation. 3108
087035 W Unexpected error occurred, cannot complete cloud snapshot restore operation 3108
087036 W No permission to use cloud snapshot delete operation 2305
087037 W A cloud object could not be found during a cloud snapshot delete operation 3108
087038 W A cloud object was found to be corrupt during cloud snapshot delete operation 3108
087039 W A cloud object was found to be corrupt during cloud snapshot delete decompression operation 3108
087040 W Unexpected error occurred, cannot complete cloud snapshot delete operation 3108
087044 W Cloud account out of space during cloud snapshot restore commit operation 2125
087045 W Cloud account out of space during cloud snapshot delete operation 2125
087046 W Transparent Cloud Tiering feature license limit exceeded. 3032
087048 W Too many node restarts have occurred, cloud backup operations paused 3104
087049 W Internal FlashCopy error on volume enabled for cloud snapshots. 2118
088000 E An IO port cannot be started 1300
088001 E A fibrechannel target port mode transition was not successful 1300
088002 W Equivalent fibre channel ports are reporting that they are connected to different fabrics 3220
088003 W A spare node in this cluster is not providing additional redundancy 1380
088004 W A spare node could not be automatically removed from the cluster 3180
089001 W Single PSU failure in bare metal server 1810
089002 W Node IP missing, only single path connection available between nodes 1811
089003 W The IP connections between nodes were broken 1812
089004 W A node rejoined cluster with identity changed 1813
981110 I iSCSI discovery occurred, configuration changes pending.  
981111 I iSCSI discovery occurred, configuration changes complete.  
981112 I iSCSI discovery occurred, no configuration changes were detected.  
988308 I Distributed array MDisk rebuild started.  
988309 I Distributed array MDisk rebuild completed.  
988310 I Distributed array MDisk copyback started.  
988311 I Distributed array MDisk copyback completed.  
988312 I Distributed array MDisk initialization started.  
988313 I Distributed array MDisk initialization completed.  
988314 I Distributed array MDisk needs resynchronization.