Error event IDs and error codes
Error codes describe a service procedure that must be followed. Each event ID that requires service has an associated error code.
Note: Service procedures that involve field-replaceable units (FRUs) do not apply to the IBM Spectrum Virtualize™ product, which is
software based. For information about possible user actions that relate to FRU replacements, refer
to your hardware manufacturer's documentation.
Error codes can be either notification type E (error) or notification type W (warning). Table 1 lists the event IDs that have corresponding error codes, and shows the error code, the notification type, and the condition for each event. For a list of informational events, which do not have associated error codes, see Informational events.
The 07nnnn event ID range refers to node errors that were logged by the system. The last 3 digits represent the error that was reported by the node. You can find these codes in the list of error codes at the end of this topic.
Event ID | Notification type | Condition | Error code |
---|---|---|---|
009020 | E | A system recovery has run. All configuration commands are blocked. | 1001 |
009040 | E | The error event log is full. | 1002 |
009052 | W | The following causes are possible:
|
1196 |
009053 | E | A node has been missing for 30 minutes. | 1195 |
009054 | W | Node has been shut down. | 1707 |
009100 | W | The software install process has failed. | 2010 |
009101 | W | Software install package cannot be delivered to all nodes. | 2010 |
009110 | Software install process stalled due to lack of redundancy | 2010 | |
009115 | Software downgrade process stalled due to lack of redundancy | 2008 | |
009150 | W | Unable to connect to the SMTP (email) server. | 2600 |
009151 | W | Unable to send mail through the SMTP (email) server. | 2601 |
009170 | W | Remote Copy feature capacity is not set. | 3030 |
009171 | W | The FlashCopy® feature capacity is not set. | 3031 |
009172 | W | The Virtualization feature has exceeded the amount that is licensed. | 3032 |
009173 | W | The FlashCopy feature has exceeded the amount that is licensed. | 3032 |
009174 | W | Remote Copy feature license limit exceeded. | 3032 |
009175 | W | Thin-provisioned volume usage not licensed. | 3033 |
009176 | W | The value set for the virtualization feature capacity is not valid. | 3029 |
009177 | E | A physical disk FlashCopy feature license is required. | 3035 |
009178 | E | A physical disk Metro Mirror and Global Mirror feature license is required. | 3036 |
009179 | E | A virtualization feature license is required. | 3025 |
009180 | E | Automatic recovery of offline node failed. | 1194 |
009181 | W | Unable to send email to any of the configured email servers. | 3081 |
009182 | W | The external virtualization feature license limit was exceeded. | 3032 |
009183 | W | Unable to connect to LDAP server. | 2251 |
009184 | W | The LDAP configuration is not valid. | 2250 |
009185 | E | The limit for the compression feature license was exceeded. | 3032 |
009186 | E | The limit for the compression feature license was exceeded. | 3032 |
009187 | E | Unable to connect to LDAP server that has been automatically configured. | 2256 |
009188 | E | Invalid LDAP configuration for automatically configured server. | 2255 |
009189 | W | A licensable feature's trial-timer has reached 0. The feature has now been deactivated. | 3082 |
009190 | W | A trial of a licensable feature will expire in 5 days. | 3083 |
009191 | W | A trial of a licensable feature will expire in 10 days. | 3084 |
009192 | W | A trial of a licensable feature will expire in 15 days. | 3085 |
009193 | W | A trial of a licensable feature will expire in 45 days. | 3086 |
009194 | W | Easy Tier feature license limit exceeded. | 3032 |
009195 | W | FlashCopy feature license limit exceeded. | 3032 |
009196 | W | External virtualization feature license limit exceeded. | 3032 |
009197 | W | Remote copy feature license limit exceeded. | 3032 |
009198 | W | System update completion is required. | 2050 |
009199 | W | System update completion has stalled. | 2012 |
009200 | W | Encryption feature license limit exceeded | 3032 |
009201 | W | The quorum application is out of date and needs to be redeployed. | 3123 |
009202 | W | System SSL certificate will expire within the next 30 days. | 3130 |
009203 | W | System SSL certificate has expired. | 2258 |
009205 | W | No active quorum device found on this cluster. | 3124 |
010002 | E | The node ran out of base event sources. As a result, the node has stopped and exited the system. | 2030 |
010003 | W | The number of device logins has reduced. | 1630 |
010004 | W | Device excluded due to excessive errors on all Managed Disks | 1640 |
010006 | E | Access beyond end of disk, or Managed Disk missing. | 2030 |
010008 | E | The block size is invalid, the capacity or LUN identity has changed during the managed disk initialization. | 1660 |
010010 | E | The managed disk is excluded because of excessive errors. | 1310 |
010011 | E | The remote port is excluded for a managed disk and node. | 1220 |
010012 | E | The local port is excluded. | 1210 |
010013 | E | The login is excluded. | 1230 |
010014 | E | The local port is excluded. | 1211 |
010015 | E | Timeout due to non-responsive device | 1340 |
010016 | E | Timeout due to lost command | 1340 |
010017 | E | A timeout has occurred as a result of excessive processing time. | 1340 |
010018 | E | An error recovery procedure has occurred. | 1370 |
010019 | E | A managed disk is reporting excessive errors. | 1310 |
010020 | E | The managed disk error count threshold has exceeded. | 1310 |
010021 | W | There are too many devices presented to the system. | 1200 |
010022 | W | There are too many managed disks presented to the system. | 1200 |
010023 | W | There are too many LUNs presented to a node. | 1200 |
010024 | W | There are too many drives presented to a system. | 1200 |
010025 | W | A disk I/O medium error has occurred. | 1320 |
010026 | W | A suitable MDisk or drive for use as a quorum disk was not found. | 1330 |
010027 | W | The quorum disk is not available. | 1335 |
010028 | W | A controller configuration is not supported. | 1625 |
010029 | E | A login transport fault has occurred. | 1360 |
010030 | E | A managed disk error recovery procedure (ERP) has occurred. The node or
controller reported the following:
|
1370 |
010031 | E | One or more MDisks on a controller are degraded. | 1623 |
010032 | W | The controller configuration limits failover. | 1625 |
010033 | E | The controller configuration uses the RDAC mode; this is not supported. | 1624 |
010034 | W | Persistent unsupported controller configuration. | 1695 |
010035 | W | Controller has quorum disabled, but quorum disk is configured | 1570 |
010040 | E | The controller system device is only connected to the node through a single initiator port. | 1627 |
010041 | E | The controller system device is only connected to the node through a single target port. | 1627 |
010042 | E | The controller system device is only connected to the nodes through a single target port. | 1627 |
010043 | E | The controller system device is only connected to the nodes through half of the expected target ports. | 1627 |
010044 | E | The controller system device has disconnected all target ports to the nodes. | 1627 |
010045 | W | Number of Device paths from the controller site allowed accessible nodes has reduced | 1630 |
010050 | W | Solid state drive failed and rebuild is required. | 1201 |
010051 | A Solid state drive is missing from the configuration | 1202 | |
010052 | E | Solid state drive offline as a result of a drive hardware error. | 1205 |
010053 | E | Solid state drive reporting PFA errors. | 1215 |
010054 | E | Solid state drive reporting too many errors. | 1215 |
010055 | W | An unrecognized SAS device. | 1665 |
010056 | E | SAS error counts exceeded the warning thresholds. | 1216 |
010057 | E | SAS errors exceeded critical thresholds. | 1216 |
010058 | E | The drive initialization failed because of an unknown block size or a block size that is not valid; an unknown capacity or a capacity that is not valid; or was not able to set the required mode pages. | 1661 |
010059 | E | Solid state drive offline due to excessive errors. | 1311 |
010060 | E | Solid state drive exceeded warning temperature threshold. | 1217 |
010061 | E | Solid state drive exceeded offline temperature threshold. | 1218 |
010062 | E | A drive exceeded the warning temperature threshold. | 1217 |
010063 | W | Drive medium error. | 1321 |
010066 | W | Controller indicates that it does not support descriptor sense for LUNs that are greater than 2 TBs. | 1625 |
010067 | W | Too many enclosures were presented to a system. | 1200 |
010068 | E | Format of the solid state drive is corrupted. | 1204 |
010069 | E | Solid state drive has incorrect block size. | 1204 |
010070 | W | Too many controller target ports were presented to the system. | 1200 |
010071 | W | Too many target ports were presented to the system from a single controller. | 1200 |
010072 | E | The drive is offline as a result of a drive hardware error. | 1680 |
010073 | E | The drive is reporting predictive failure analysis (PFA) errors. | 1680 |
010080 | E | The drive is reporting too many errors. | 1680 |
010081 | E | The drive format is corrupted. | 1206 |
010082 | E | The block size for the drive was incorrect. | 1206 |
010083 | E | The drive is offline due to excessive errors. | 1680 |
010084 | E | The error counts for the SAS drive exceeded the warning thresholds. | 1285 |
010085 | W | The SAS device was not recognized. | 1666 |
010086 | W | The SAS enclosure was not recognized. | 1666 |
010087 | W | The SAS device was not able to be identified. | 1666 |
010088 | E | There were excessive medium errors on the drive. | 1680 |
010089 | E | There were excessive overall timeout errors on the drive. | 1680 |
010090 | E | There were excessive times when the drive stopped. | 1680 |
010091 | E | A drive failed validation testing. | 1680 |
010092 | E | Excessive medium errors on the solid state drive. | 1215 |
010093 | E | Excessive overall timeout errors on the solid state drive. | 1204 |
010094 | E | Login excluded. | 1231 |
010095 | E | Drive failed. | 1687 |
010096 | E | The drive initialization failed because of an unknown block size or a block size that is not valid; an unknown capacity or a capacity that is not valid; or was not able to set the required mode pages. | 1680 |
010097 | E | A drive is reporting excessive errors. | 1685 |
010098 | W | There are too many drives presented to a system. | 1200 |
010100 | W | Incorrect connection detected to a port. | 1669 |
010101 | E | Too many long IOs to drive. | 1215 |
010102 | E | A drive is reported as continuously slow with contributory factors. | 1215 |
010103 | E | Too many long IOs to drive (Mercury drives). | 1215 |
010104 | E | A drive is reported as continuously slow with contributory factors (Mercury drives). | 1215 |
010105 | W | Storage system connected to unsupported port | 2080 |
010106 | E | Drive reporting too many t10dif errors. | 1680 |
010107 | W | Encrypting MDisk is no longer encrypted | 2580 |
010110 | W | Drive firmware download canceled because of system changes. | 3090 |
010111 | W | Drive firmware download canceled because of a drive download problem. | 3090 |
010117 | W | A disk controller is not accessible from a node allowed to access the device by site policy | 1627 |
010118 | W | Too many drives attached to the system. | 1179 |
010119 | W | Drive data integrity error. | 1322 |
010120 | W | A member drive has been forced to turn off protection information support. | 2035 |
010121 | E | Drive exchange required. | 1693 |
010123 | W | Performance of external MDisk has changed. | 2115 |
010124 | W | iSCSI session excluded. | 1230 |
010125 | W | A Flash drive is expected to fail within six months due to limited write endurance. | 1215 |
010126 | W | A Flash drive with high write endurance usage rate. | 2560 |
020001 | E | There are too many medium errors on the MDisk. | 1610 |
020002 | E | A storage pool is offline. | 1620 |
020003 | W | There are insufficient virtual extents. | 2030 |
020008 | E | Storage optimization services disabled. | 3023 |
029001 | E | The MDisk has bad blocks. | 1840 |
029002 | W | The system failed to create a bad block because MDisk already has the maximum number of allowed bad blocks. | 1226 |
029003 | W | The system failed to create a bad block because the system already has the maximum number of allowed bad blocks. | 1225 |
030000 | W | FlashCopy prepare failed due to cache flush failure. | 1900 |
030010 | W | FlashCopy has been stopped due to the error indicated in the data. | 1910 |
030020 | W | Unrecovered FlashCopy mappings. | 1895 |
045001 | E | One or more power supply unit fans have failed. | 1124 |
045002 | E | A fan is operating outside the expected range. | 1126 |
045003 | E | There was a fan status communications failure. | 1126 |
045004 | W | The power supply unit is not installed. | 1128 |
045005 | W | The power supply unit has indicated an input power failure. | 1138 |
045006 | E | The power supply unit has indicated an output failure. | 1126 |
045007 | E | The power supply unit has failed. | 1124 |
045008 | E | Cannot communicate with the power supply unit. | 1148 |
045009 | E | The PSU type is not valid for this enclosure type. | 1124 |
045010 | E | The power supply unit type is unknown to this product. | 1124 |
045011 | E | PSU 11S serial number not valid. | 1124 |
045012 | W | The canister temperature is at the warning level. | 1098 |
045013 | W | The canister temperature is at the critical level. | 1095 |
045014 | E | A SAS cable was excluded due to internal errors. | 1260 |
045015 | E | A SAS cable was excluded because too many change events were caused. | 1260 |
045016 | E | A SAS cable was excluded. | 1255 |
045017 | E | A SAS cable is operating at a reduced speed. | 1260 |
045018 | E | A SAS cable was excluded because frames were dropped. | 1260 |
045019 | E | A SAS cable was excluded because the enclosure discovery timed out. | 1260 |
045020 | W | A SAS cable is not present. | 1265 |
045021 | W | A canister was removed from the system. | 1036 |
045022 | E | A canister has been in a degraded state for too long and cannot be recovered. | 1034 |
045023 | E | A canister is encountering communication problems. | 1038 |
045024 | E | The canister VPD is not valid. | 1032 |
045025 | E | The canister has experienced too many resets. | 1032 |
045026 | E | The drive slot is causing the network to be unstable. | 1686 |
045027 | E | The drive slot is not running at 6 Gbps. | 1686 |
045028 | E | The drive slot is dropping frames. | 1686 |
045029 | E | The drive is visible through only one SAS port. | 1686 |
045031 | E | The drive power control is not functional. | 1008 |
045032 | E | A drive is present in the slot but does not respond to any SCSI or SAS commands. | 1686 |
045033 | E | The drive slot contains a device that is not responding to queries. | 1685 |
045034 | E | The managed enclosure is not visible from any node canisters. | 1042 |
045035 | E | The electronics in the enclosure has failed. | 1694 |
045036 | E | The electronics in the enclosure has experienced a critical failure. | 1008 |
045037 | E | The SAS network has too many errors. | 1048 |
045038 | E | The SAS network has too many errors. | 1048 |
045040 | W | The firmware update for the enclosure component has failed. | 3015 |
045041 | W | More than one initiator port was detected on the same strand. | 1005 |
045042 | W | The order of the enclosures is different on each strand. | 1005 |
045044 | W | Multiple canisters are connected to a single canister port. | 1005 |
045045 | W | Canister one is connected to canister two. | 1005 |
045046 | W | An enclosure is connected to more than one I/O group. | 1005 |
045047 | W | A managed enclosure is connected to the wrong I/O group. | 1005 |
045048 | W | An enclosure is connected to more than one chain. | 1005 |
045049 | W | Too many canisters are connected to a strand. | 1005 |
045050 | W | The canister is connected to the wrong port. | 1005 |
045051 | E | A SAS cable is excluded because of single port active drives. | 1260 |
045052 | W | More than one canister was detected at the same hop count. | 1005 |
045053 | E | The node location is not able to be detected. | 1031 |
045054 | E | An enclosure display cannot be updated. | 1694 |
045055 | E | There is an enclosure battery fault. | 1118 |
045056 | E | An enclosure battery is missing. | 1112 |
045057 | E | An enclosure battery is nearing end of life. | 1114 |
045058 | E | An enclosure battery is at end of life. | 1113 |
045060 | E | Drive slot cannot be excluded. | 1048 |
045062 | W | An enclosure battery conditioning is required but not possible. | 1131 |
045063 | E | There was an enclosure battery communications error. | 1116 |
045064 | W | A SAS port is active, but no enclosures can be detected. | 1005 |
045065 | E | There is a connectivity problem between a canister and an enclosure. | 1036 |
045066 | E | The FRU identity of the enclosure is not valid. | 1008 |
045067 | W | A new enclosure FRU was detected and needs to be configured. | 1041 |
045068 | E | The internal device on a node canister was excluded because of too many change events. | 1034 |
045069 | E | The internal connector on the node canister was excluded as the cause of single ported drives. | 1034 |
045070 | W | The canister temperature sensor cannot be read. | 1034 |
045071 | W | The enclosure contains both a node canister and an expansion canister. | 1037 |
045072 | E | The discovery failed to complete. | 1048 |
045073 | E | The VPD for the enclosure cannot be read. | 1048 |
045074 | W | The PSU temperature is at the warning level. | 1098 |
045075 | W | The PSU temperature is at the critical level. | 1095 |
045076 | E | Error reading PSU temperature sensor. | 1124 |
045077 | E | Attempts to exclude connector have failed. | 1260 |
045080 | E | There are too many self-initiated resets on the enclosure. | 1048 |
045081 | E | The PSU has attempted too many internal recovery actions. | 1124 |
045082 | E | The slots are powered off. | 1048 |
045083 | W | The enclosure configuration is not supported. | 1005 |
045084 | W | There are too many SDE enclosures on strand. | 1005 |
045085 | W | The SDE is detected in a chassis that is not valid. | 1005 |
045086 | E | Node canister internal connector failed because of dropped frames. | 1034 |
045102 | W | SAS cable is not working at full capacity | 1260 |
045103 | E | An attempt to automatically configure a reseated or replaced drive has failed. | 1686 |
045104 | W | Drives are single ported due to a spare node | 3200 |
045105 | E | Enclosure secondary expander module has failed | 1267 |
045106 | E | Enclosure secondary expander module FRU identity is not valid | 1266 |
045107 | E | Enclosure secondary expander module temperature sensor cannot be read | 1267 |
045108 | E | Enclosure secondary expander module temperature has passed warning threshold | 1098 |
045109 | E | Enclosure secondary expander module temperature has passed critical threshold | 1095 |
045110 | E | Enclosure display panel is not installed | 1268 |
045111 | E | Enclosure display panel temperature sensor cannot be read | 1268 |
045112 | E | Enclosure display panel temperature has passed warning threshold | 1098 |
045113 | E | Enclosure display panel temperature has passed critical threshold | 1095 |
045114 | E | Enclosure secondary expander module connector excluded due to too many change events | 1267 |
045119 | E | Enclosure display panel VPD cannot be read | 1268 |
045120 | E | Enclosure secondary expander module is missing | 1267 |
045121 | E | Enclosure secondary expander module connector excluded due to dropped frames | 1267 |
045122 | E | Enclosure secondary expander module connector is excluded and cannot be unexcluded | 1267 |
045123 | E | Enclosure secondary expander module connectors excluded as the cause of single ported drives | 1267 |
045124 | E | Enclosure secondary expander module leaf expander connector excluded as the cause of single ported drives | 1267 |
050001 | W | The Metro Mirror or Global Mirror relationship cannot be recovered. | 1700 |
050002 | W | A Metro Mirror or Global Mirror relationship or consistency group exists within a system, but its partnership has been deleted. | 3080 |
050010 | W | A Global Mirror relationship has stopped because of a persistent I/O error. | 1920 |
050011 | W | A remote copy has stopped because of a persistent I/O error. | 1915 |
050020 | W | Remote Copy relationship or consistency groups lost synchronization. | 1720 |
050030 | W | There are too many system partnerships. The number of partnerships has been reduced. | 1710 |
050031 | W | There are too many system partnerships. The system has been excluded. | 1710 |
050040 | W | Background copy process for the remote copy was blocked. | 1960 |
050041 | W | Partner cluster IP address unreachable | 2021 |
050042 | W | Cannot authenticate with partner cluster. | 2022 |
050043 | W | Unexpected cluster ID for partner cluster | 2023 |
050050 | E | The Global Mirror secondary volume is offline. The relationship has pinned hardened write data for this volume. | 1925 |
050060 | E | The Global Mirror secondary volume is offline due to missing I/O group partner node. The relationship has pinned hardened write data for this volume but the node containing the required data is currently offline. | 1730 |
050070 | E | Global Mirror performance is likely to be impacted. A large amount of pinned data for the offline volumes has reduced the resource available to the global mirror secondary disks. | 1925 |
050080 | W | HyperSwap® volume has lost synchronization between sites. | 1940 |
050081 | W | HyperSwap consistency group has lost synchronization between sites. | 1940 |
050082 | E | Compression has stopped unexpectedly | 3131 |
060001 | W | A thin-provisioned volume copy is offline because of insufficient space. | 1865 |
060002 | E | A thin-provisioned volume copy is offline because of corrupt metadata. | 1862 |
060003 | E | A thin-provisioned volume copy is offline because of a failed repair. | 1860 |
060004 | W | A compressed volume copy is offline because of insufficient space. | 1865 |
060005 | E | A compressed volume copy is offline because of corrupt metadata. | 1862 |
060006 | E | A compressed volume copy is offline because of a failed repair. | 1860 |
060007 | E | A compressed volume copy has bad blocks. | 1850 |
062001 | W | System is unable to mirror medium error. | 1950 |
062002 | E | Mirrored volume is offline because it cannot synchronize data. | 1870 |
062003 | W | Repair of a mirrored volume stopped because of difference. | 1600 |
064001 | W | A host port has more than four logins to a node | 2016 |
070534 | E | System board fault | 1026 |
070541 | E | Multiple hardware failures | 1184 |
070547 | E | Pluggable TPM is missing or broken | 1051 |
070551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible | 1192 |
070572 | E | Battery protection temporarily unavailable; both batteries are expected to be available soon. | 1473 |
070573 | E | Node software inconsistent | 1192 |
070700 | W | Fibre Channel adapter missing | 1045 |
070701 | E | Fibre Channel adapter failed | 1046 |
070702 | E | Fibre Channel adapter PCI error | 1046 |
070703 | E | Fibre Channel adapter degraded | 1046 |
070704 | W | Fewer Fibre Channel ports operational. | 1060 |
070705 | W | Fewer Fibre Channel I/O ports operational. | 1450 |
070706 | W | Fibre Channel clustered system path failure. | 1550 |
070711 | E | SAS adapter failed | 1046 |
070712 | E | SAS adapter PCI error | 1046 |
070713 | E | SAS adapter degraded | 1046 |
070715 | W | Fewer SAS ports operational | 1046 |
070717 | W | SAS ports degraded | 1046 |
070718 | W | SASA port has unsupported SAS device | 1046 |
070720 | W | Ethernet adapter missing | 1045 |
070721 | E | Ethernet adapter failed | 1046 |
070722 | E | Ethernet adapter PCI error | 1046 |
070723 | E | Ethernet adapter degraded | 1046 |
070724 | W | Fewer Ethernet ports | 1046 |
070730 | Bus adapter missing | 1192 | |
070731 | Bus adapter failed | 1192 | |
070732 | Bus adapter PCI error | 1192 | |
070733 | Bus adapter degraded | 1192 | |
070734 | Fewer bus ports operational | 1006 | |
070747 | W | Technician connected. | 747 |
070760 | E | Voltage fault | 1110 |
070761 | E | Voltage high | 1100 |
070762 | E | Voltage low | 1105 |
070765 | E | Fan error | 1089 |
070768 | W | Ambient temperature warning | 1094 |
070769 | W | CPU temperature warning | 1093 |
070770 | W | Shutdown temperature reached | 1092 |
070830 | W | Encryption key required | 1328 |
070831 | W | Encryption key invalid | 2555 |
070832 | W | Encryption key not found | 2555 |
070833 | W | USB device (such as hub) unsupported | 2555 |
070836 | W | Encryption key required | 1328 |
070842 | W | Fibre Channel IO port mapping failed | 1059 |
070860 | W | Fibre-channel network fabric is too big. | 1800 |
071500 | W | Incorrect enclosure | 1021 |
071501 | E | Incorrect slot | 1192 |
071502 | E | No enclosure id and cannot get status from partner | 1192 |
071503 | E | Incorrect enclosure type | 1192 |
071504 | E | No enclosure id & partner matches | 1192 |
071505 | E | No enclosure id and partner has cluster data does not match | 1192 |
071506 | E | No enclosure id and no cluster state on partner | 1192 |
071507 | E | No enclosure id and no cluster state | 1192 |
071508 | W | Cluster id different between enclosure and node | 1023 |
071509 | E | Cannot read enclosure identity | 1036 |
071510 | E | The detected memory size does not match the expected memory size | 1032 |
071522 | E | The system board processor has failed. | 1034 |
071523 | E | Internal disk file system is damaged | 1187 |
071524 | E | Unable to update BIOS settings | 1034 |
071525 | E | Unable to update system board service processor firmware | 1034 |
071528 | W | Ambient temperature too high while system starting | 1092 |
071535 | E | Canister internal PCIe switch failed | 1034 |
071541 | E | Multiple hardware failures | 1184 |
071547 | E | Pluggable TPM is missing or broken | 1051 |
071550 | W | Cannot form cluster due to lack of cluster resources | 1192 |
071551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible | 1192 |
071556 | W | Duplicate WWNN detected on SAN | 1133 |
071562 | E | The node's hardware configuration does not meet minimum requirements | 1034 |
071564 | W | Too many software failures | 1188 |
071565 | E | The node's internal drive is failing. | 1032 |
071569 | E | CPU over temp. | 1032 |
071573 | E | Node software inconsistent | 1187 |
071574 | E | Node software is damaged | 1187 |
071576 | E | Cluster state and configuration data cannot be read | 1032 |
071578 | E | State data was not saved on power loss | 1194 |
071671 | W | The available battery charge is not enough to allow the node canister to start . Two batteries are charging. | 1176 |
071672 | W | The available battery charge is not enough to allow the node canister to start . One battery is charging. | 1176 |
071673 | E | The available battery charge is not enough to allow the node canister to start . No batteries are charging. | 1004 |
071690 | W | Node held in service state | 1189 |
071700 | W | Fibre Channel adapter missing | 1032 |
071701 | E | Fibre Channel adapter failed | 1032 |
071702 | E | Fibre Channel adapter PCI error | 1034 |
071703 | E | Fibre Channel adapter degraded | 1034 |
071704 | W | Fewer Fibre Channel ports operational. | 1061 |
071705 | W | Fewer Fibre Channel I/O ports operational. | 1450 |
071706 | W | Fibre Channel clustered system path failure. | 1550 |
071710 | W | SAS adapter missing | 1032 |
071711 | E | SAS adapter failed | 1032 |
071712 | E | SAS adapter PCI error | 1034 |
071713 | E | SAS adapter degraded | 1034 |
071715 | W | Fewer SAS ports operational | 1034 |
071717 | W | SAS ports degraded | 1034 |
071718 | W | SASA port has unsupported SAS device | 1034 |
071720 | W | Ethernet adapter missing | 1032 |
071721 | E | Ethernet adapter failed | 1032 |
071722 | E | Ethernet adapter PCI error | 1034 |
071723 | E | Ethernet adapter degraded | 1034 |
071724 | W | Fewer Ethernet ports | 1401 |
071730 | W | Bus adapter missing | 1032 |
071731 | E | Bus adapter failed | 1032 |
071732 | E | Bus adapter PCI error | 1034 |
071733 | E | Bus adapter degraded | 1034 |
071734 | W | Fewer bus ports operational | 1006 |
071747 | W | Technician connected. | 747 |
071768 | W | Ambient temperature warning | 1094 |
071769 | W | CPU temperature warning | 1093 |
071781 | W | Battery cold | 1156 |
071782 | W | Battery hot | 1157 |
071786 | E | Battery VPD checksum | 1154 |
071830 | W | Encryption key required | 1328 |
071831 | W | Encryption key invalid | 2555 |
071832 | W | Encryption key not found | 2555 |
071833 | W | USB device (such as hub) unsupported | 2555 |
071836 | W | Encryption key required | 1328 |
071850 | W | Canister battery is nearing end of life | 1159 |
072500 | W | Incorrect enclosure | 1021 |
072501 | E | Incorrect slot | 1192 |
072502 | E | No enclosure id and cannot get status from partner | 1192 |
072503 | E | Incorrect enclosure type | 1192 |
072504 | E | No enclosure id & partner matches | 1192 |
072505 | E | No enclosure id and partner has cluster data that does not match | 1192 |
072506 | E | No enclosure id and no cluster state on partner | 1192 |
072507 | E | No enclosure id and no cluster state | 1192 |
072508 | W | Cluster id different between enclosure and node | 1023 |
072509 | E | Cannot read enclosure identity | 1036 |
072510 | E | The detected memory size does not match the expected memory size | 1032 |
072522 | E | The system board processor has failed | 1033 |
072523 | E | Internal disk file system is damaged | 1187 |
072525 | E | Unable to update system board service processor firmware | 1034 |
072535 | E | Canister internal PCIe switch failed | 1192 |
072541 | E | Multiple hardware failures | 1184 |
072550 | W | Cannot form cluster due to lack of cluster resources | 1192 |
072551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible | 1192 |
072556 | E | Duplicate WWNN detected on SAN | 1133 |
072562 | E | The node's hardware configuration does not meet minimum requirements | 1034 |
072564 | E | Too many software failures | 1188 |
072565 | E | The node's internal drive is failing. | 1032 |
072569 | E | CPU over temp. | 1032 |
072573 | E | Node software inconsistent | 1187 |
072574 | E | Node software is damaged | 1187 |
072576 | E | Cluster state and configuration data cannot be read | 1032 |
072578 | E | State data was not saved on power loss | 1194 |
072650 | W | The canister battery is not supported. | 1149 |
072651 | W | The canister battery is missing. | 1153 |
072652 | E | The canister battery has failed. | 1154 |
072655 | E | Canister battery communications error | 1158 |
072656 | W | Canister battery has insufficient charge to support a firehose dump | 1197 |
072690 | W | Node held in service state | 1189 |
072700 | W | Fibre Channel adapter missing | 1045 |
072701 | E | Fibre Channel adapter failed | 1046 |
072702 | E | Fibre Channel adapter PCI error | 1046 |
072703 | E | Fibre Channel adapter degraded | 1046 |
072704 | W | Fewer Fibre Channel ports operational. | 1062 |
072705 | W | Fewer Fibre Channel I/O ports operational. | 1450 |
072706 | W | Fibre Channel clustered system path failure. | 1550 |
072710 | W | SAS adapter missing | 1045 |
072711 | E | SAS adapter failed | 1046 |
072712 | E | SAS adapter PCI error | 1046 |
072713 | E | SAS adapter degraded | 1046 |
072715 | W | Fewer SAS ports operational | 1046 |
072717 | W | SAS ports degraded | 1046 |
072718 | W | SASA port has unsupported SAS device | 1046 |
072720 | W | Ethernet adapter missing | 1045 |
072721 | E | Ethernet adapter failed | 1046 |
072722 | E | Ethernet adapter PCI error | 1046 |
072723 | E | Ethernet adapter degraded | 1046 |
072724 | W | Fewer Ethernet ports | 1402 |
072730 | W | Bus adapter missing | 1032 |
072731 | E | Bus adapter failed | 1032 |
072732 | E | Bus adapter PCI error | 1032 |
072733 | E | Bus adapter degraded | 1032 |
072734 | W | Fewer bus ports operational | 1006 |
072766 | E | CMOS error | 1670 |
072840 | W | A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. | 1198 |
072841 | W | A supported hardware change was made to this node. User action is required to activate the new hardware. | 1199 |
072850 | W | Canister battery is nearing end of life | 1159 |
072860 | W | Fibre-channel network fabric is too big. | 1800 |
073003 | W | The Fibre Channel ports are not operational. | 1060 |
073004 | E | Fibre Channel adapter detected PCI bus error. | 1012 |
073005 | E | System path has a failure. | 1550 |
073006 | W | The SAN is not correctly zoned. As a result, more than 512 ports on the SAN have logged into one Storwize® V3500 port. | 1800 |
073007 | W | There are fewer Fibre Channel ports operational than are configured. | 1061 |
073305 | W | Fibre Channel speed has changed. | 1065 |
073310 | E | Duplicate Fibre Channel frame is detected. | 1203 |
073402 | E | The Fibre Channel adapter has a failure. | 1032 |
073404 | E | Fibre Channel adapter has detected PCI bus error. | 1032 |
073500 | W | Incorrect enclosure | 1021 |
073501 | E | The canister position is not correct. | 1192 |
073502 | E | No enclosure id and cannot get status from partner | 1192 |
073503 | E | The enclosure type is not correct. | 1192 |
073504 | E | The enclosure identity and partner does not match. | 1192 |
073505 | E | No enclosure id and partner has cluster data that does not match | 1192 |
073506 | E | The state and enclosure identity cannot be detected on the partner. | 1192 |
073507 | E | The enclosure identity and node state cannot be detected. | 1192 |
073508 | W | The system identity is different on the enclosure and the node. | 1023 |
073509 | E | The enclosure identity cannot be read. | 1036 |
073510 | E | Detected memory size does not match the expected memory size. | 1032 |
073512 | E | Enclosure VPD is inconsistent. | 1008 |
073522 | E | The system board service processor has failed. | 1034 |
073523 | W | The internal disk file system of the node is damaged. | 1187 |
073524 | E | Unable to update BIOS settings | 1034 |
073525 | E | Unable to update the service processor firmware of the system board. | 1034 |
073528 | E | Ambient temperature is too high during system startup. | 1098 |
073535 | E | The internal PCIe switch of the node canister failed. | 1034 |
073541 | E | Multiple hardware failures | 1184 |
073550 | W | System cannot be created because of lack of resources. | 1192 |
073551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible | 1192 |
073556 | W | Duplicate WWNN are detected on the SAN. | 1133 |
073562 | E | The node hardware does not meet the minimum requirements. | 1034 |
073564 | W | Too many software failures | 1188 |
073565 | E | The internal drive of the node is failing. | 1032 |
073569 | E | CPU over temp. | 1032 |
073573 | E | Node software inconsistent (not raised on this platform). | 1187 |
073574 | E | The system data cannot be read. | 1187 |
073576 | E | Cluster state and configuration data cannot be read | 1032 |
073578 | E | The system data was not saved when power was lost. | 1194 |
073650 | W | The canister battery is not supported. | 1149 |
073651 | E | The canister battery is missing. | 1153 |
073652 | E | The canister battery has failed. | 1154 |
073653 | E | The canister battery's temperature is too low. | 1156 |
073654 | E | The canister battery's temperature is too high. | 1157 |
073655 | E | The canister has a battery communications fault. | 1158 |
073656 | E | The canister battery has insufficient charge. | 1184 |
073690 | W | Node held in service state | 1189 |
073700 | E | The Fibre Channel adapter is missing. | 1045 |
073701 | E | The Fibre Channel adapter failed. | 1046 |
073702 | E | The Fibre Channel adapter has a PCI error. | 1046 |
073703 | E | The Fibre Channel adapter is degraded. | 1045 |
073704 | W | Fewer Fibre Channel ports are operational. | 1061 |
073705 | W | Fewer Fibre Channel I/O ports are operational. | 1450 |
073710 | E | The SAS adapter is missing. | 1045 |
073711 | E | The SAS adapter has failed. | 1046 |
073712 | E | The SAS adapter has a PCI error. | 1046 |
073713 | E | The SAS adapter is degraded. | 1046 |
073715 | W | Fewer SAS ports operational | 1046 |
073717 | W | SAS ports degraded | 1046 |
073718 | W | SASA port has unsupported SAS device | 1669 |
073720 | E | The Ethernet adapter is missing. | 1045 |
073721 | E | The Ethernet adapter has failed. | 1046 |
073722 | E | Ethernet adapter PCI error. | 1046 |
073723 | E | Ethernet adapter degraded. | 1046 |
073724 | W | Fewer Ethernet ports are operational. | 1401 |
073730 | E | The bus adapter is missing. | 1032 |
073731 | E | The bus adapter has failed. | 1032 |
073732 | E | The bus adapter has a PCI error. | 1032 |
073733 | E | The bus adapter is degraded. | 1032 |
073734 | W | The inter-canister PCIe has a link failure. | 1006 |
073748 | W | Technician port remains enabled. | 748 |
073766 | E | CMOS error | 1670 |
073768 | W | Ambient temperature warning. | 1094 |
073769 | W | CPU temperature warning. | 1093 |
073820 | W | The node canister has detected that it has a hardware type that is not compatible with the control enclosure MTM | 3020 |
073830 | W | Encryption key required | 1328 |
073831 | W | Encryption key invalid | 2555 |
073832 | W | Encryption key not found | 2555 |
073833 | W | USB device (such as hub) unsupported | 2555 |
073836 | W | Encryption key required | 1328 |
073840 | E | Detected hardware is not a valid configuration. | 1198 |
073841 | E | Detected hardware needs activation. | 1199 |
073850 | W | Canister battery is nearing end of life | 1159 |
073860 | W | The fabric is too large. | 1800 |
074001 | W | System is unable to determine VPD for a FRU. | 2040 |
074002 | E | The node warm started after a software error. | 2030 |
074003 | W | A connection to a configured remote system has been lost because of a connectivity problem. | 1715 |
074004 | W | A connection to a configured remote system has been lost because of too many minor errors. | 1716 |
074500 | W | Incorrect enclosure | 1021 |
074501 | E | Incorrect slot | 1192 |
074502 | E | No enclosure id and cannot get status from partner | 1192 |
074503 | E | Incorrect enclosure type | 1192 |
074504 | E | No enclosure id & partner matches | 1192 |
074505 | E | No enclosure id and partner has cluster data that does not match | 1192 |
074506 | E | No enclosure id and no cluster state on partner | 1192 |
074507 | E | No enclosure id and no cluster state | 1192 |
074508 | W | Cluster id different between enclosure and node | 1023 |
074509 | E | Cannot read enclosure identity | 1043 |
074510 | E | The detected memory size does not match the expected memory size | 1039 |
074512 | E | Enclosure VPD is inconsistent | 1029 |
074521 | E | Unable to detect any fibre-channel adapter | 1192 |
074522 | E | The system board processor has failed | 1088 |
074523 | E | Internal disk file system is damaged | 1187 |
074524 | E | Unable to update BIOS settings | 1034 |
074525 | E | Unable to update system board service processor firmware | 1192 |
074528 | W | Ambient temperature too high while system starting | 1087 |
074534 | E | System board fault | 1039 |
074535 | E | Canister internal PCIe switch failed | 1034 |
074536 | E | A device on the system board is too hot | 1192 |
074538 | E | PCI Riser too hot | 1192 |
074541 | E | Multiple hardware failures | 1184 |
074550 | W | Cannot form cluster due to lack of cluster resources | 1192 |
074551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible | 1192 |
074556 | W | Duplicate WWNN detected on SAN | 1133 |
074562 | E | The node's hardware configuration does not meet minimum requirements | 1034 |
074564 | E | Too many software failures | 1188 |
074565 | E | The node's internal drive is failing. | 1039 |
074569 | E | CPU over temp. | 1192 |
074573 | E | Node software inconsistent | 1192 |
074574 | E | Node software is damaged | 1187 |
074576 | E | Cluster state and configuration data cannot be read | 1039 |
074578 | E | State data was not saved on power loss | 1194 |
074650 | W | The canister battery is not supported. | 1192 |
074651 | W | The canister battery is missing. | 1192 |
074652 | E | The canister battery has failed. | 1192 |
074653 | W | The canister battery is below minimum operating temperature. | 1192 |
074654 | W | The canister battery is above maximum operating temperature. | 1192 |
074655 | E | Canister battery communications error | 1192 |
074656 | W | Canister battery has insufficient charge to support a firehose dump | 1192 |
074657 | E | Not enough battery to support graceful shutdown. | 1111 |
074690 | W | Node held in service state | 1189 |
074710 | W | SAS adapter missing | 1192 |
074711 | E | SAS adapter failed | 1192 |
074712 | E | SAS adapter PCI error | 1192 |
074713 | E | SAS adapter degraded | 1192 |
074715 | W | Fewer SAS ports operational | 1192 |
074717 | W | SAS ports degraded | 1192 |
074718 | W | SASA port has unsupported SAS device | 1192 |
074720 | W | Ethernet adapter missing | 1039 |
074721 | E | Ethernet adapter failed | 1039 |
074722 | E | Ethernet adapter PCI error | 1034 |
074723 | E | Ethernet adapter degraded | 1034 |
074724 | W | Fewer Ethernet ports | 1401 |
074730 | W | Bus adapter missing | 1039 |
074731 | E | Bus adapter failed | 1039 |
074732 | E | Bus adapter PCI error | 1034 |
074733 | E | Bus adapter degraded | 1034 |
074734 | W | Fewer bus ports operational | 1007 |
074768 | W | Ambient temperature warning | 1099 |
074830 | W | Encryption key required | 1328 |
074831 | W | Encryption key invalid | 2555 |
074832 | W | Encryption key not found | 2555 |
074833 | W | USB device (such as hub) unsupported | 2555 |
074840 | W | A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. | 1198 |
074841 | W | A supported hardware change was made to this node. User action is required to activate the new hardware. | 1199 |
076001 | E | The internal disk for a node has failed. | 1030 |
076002 | E | The hard disk is full and cannot capture any more output. | 2030 |
076401 | E | One of the two power supply units in the node has failed. | 1096 |
076402 | E | One of the two power supply units in the node cannot be detected. | 1096 |
076403 | E | One of the two power supply units in the node is without power. | 1097 |
076502 | E | The PCIe lanes on a high-speed SAS adapter are degraded. | 1121 |
076503 | E | A PCI bus error occurred on a high-speed SAS adapter. | 1121 |
076504 | E | A high-speed SAS adapter requires a PCI bus reset. | 1122 |
076505 | E | The SAS adapter has an internal fault. | 1121 |
076511 | E | A high-speed SAS controller is missing. | 1032 |
076512 | E | The PCIe lanes on a high-speed SAS adapter are degraded. | 1032 |
076513 | E | A PCI bus error occurred on a high-speed SAS adapter. | 1032 |
076514 | E | A high-speed SAS adapter requires a PCI bus reset. | 1034 |
077001 | E | The node service processor indicated Fan 1 failure. | 1070 |
077002 | E | The node service processor indicated Fan 2 failure. | 1070 |
077003 | E | The node service processor indicated Fan 3 failure. | 1070 |
077004 | E | The node service processor indicated Fan 4 failure. | 1070 |
077005 | E | The node service processor indicated Fan 5 failure. | 1071 |
077011 | E | The node service processor indicated that the ambient temperature threshold was exceeded. | 1075 |
077012 | E | The node service processor indicated temperature warning threshold was exceeded. | 1076 |
077013 | E | The node service processor indicated soft or hard shutdown temperature threshold was exceeded. | 1077 |
077021 | E | The node service processor indicated 12-volt supply has exceeded thresholds. | 1080 |
077022 | E | The node service processor indicated 5-volt supply has exceeded thresholds. | 1080 |
077023 | E | The node service processor indicated 3.3-volt supply has exceeded thresholds. | 1080 |
077024 | E | The node service processor indicated 2.5-volt supply has exceeded thresholds. | 1081 |
077025 | E | The node service processor indicated 1.5-volt supply has exceeded thresholds. | 1081 |
077026 | E | The node service processor indicated 1.25-volt supply has exceeded thresholds. | 1081 |
077027 | E | The node service processor indicated that the CPU supply has exceeded thresholds. | 1081 |
079500 | W | The limit on the number of system secure shell (SSH) sessions has been reached. | 2500 |
079501 | W | Unable to access the Network Time Protocol (NTP) network time server. | 2700 |
079503 | W | Unable to connect to NTP server that has been automatically configured. | 2702 |
079504 | W | Hardware configurations of nodes differ in an I/O group. | 1470 |
079505 | W | Stretch cluster reconfiguration is required to restore a dual site configuration | 1178 |
081002 | E | An Ethernet port failure has occurred. | 1401 |
082001 | E | A server error has occurred. | 2100 |
082002 | W | Service failure has occured. | 2100 |
083001 | E | System failed to communicate with UPS. | 1145 |
083002 | E | UPS output loading was unexpectedly high. | 1165 |
083003 | E | Battery has reached end of life. | 1190 |
083004 | E | UPS battery has a fault. | 1180 |
083005 | E | UPS electronics has a fault. | 1170 |
083006 | E | UPS frame has a fault. | 1175 |
083007 | E | UPS is overcurrent. | 1160 |
083008 | E | UPS has a fault but no specific FRU is identified. | 1185 |
083009 | E | The UPS has detected an input power fault. | 1140 |
083010 | E | UPS has a cabling error. | 1150 |
083011 | E | UPS ambient temperature threshold has exceeded. | 1135 |
083012 | E | UPS ambient temperature is high. | 3000 |
083013 | E | UPS crossed-cable test is bypassed because of an internal UPS software error. | 3010 |
084000 | W | An array MDisk has deconfigured members and has lost redundancy. | 1689 |
084050 | W | An array MDisk is expected to fail within six months due to limited write endurance of member drives | 3060 |
084100 | E | An array MDisk is corrupt because of lost metadata. | 1240 |
084200 | W | Array MDisk has taken a spare member that does not match array goals. | 1692 |
084201 | W | An array has members that are located in a different I/O group. | 1688 |
084300 | W | An array MDisk is no longer protected by an appropriate number of suitable spares. | 1690 |
084301 | W | No spare protection exists for one or more array MDisks. | 1690 |
084302 | W | Distributed array MDisk has fewer rebuild areas available than threshold. | 1690 |
084400 | W | A background scrub process has found an inconsistency between data and parity on the array. | 1691 |
084420 | W | Array MDisk has been forced to disable hardware data integrity checking on member drives. | 2035 |
084500 | E | An array MDisk is offline. The metadata for the inflight writes is on a missing node. | 1243 |
084600 | E | An array MDisk is offline. Metadata on the missing node contains needed state information. | 1243 |
084700 | W | Array response time too high. | 1750 |
084701 | W | Distributed array MDisk member slow write count threshold exceeded. | 1750 |
084800 | E | Distributed array MDisk offline due to I/O timeout. | 1340 |
085047 | W | Battery reconditioning required but not possible | 1131 |
085052 | E | Interface card has degraded PCI link | 1039 |
085055 | W | External FC data link degraded | 1064 |
085056 | W | External IB data link degraded | 1064 |
085063 | E | Canister is missing an interface card | 1045 |
085091 | W | External iSCSI port not operational | 1403 |
085092 | W | Too many ISCSI host logins | 1803 |
085118 | W | System update halted | 2010 |
085160 | W | Check the air filter | 1820 |
085161 | E | Array data compromised | 1048 |
085198 | W | Too many enclosures visible on fabric | 1807 |
085199 | W | Enclosure visible on fabric managed by another system | 1706 |
085200 | W | Cabling error. Internal cabling connectivity has changed. | 1440 |
085201 | W | Enclosure connectivity undetermined. Connectivity to an enclosure can no longer be determined | 1440 |
085202 | W | Minimal enclosure connectivity not met. | 1705 |
085203 | W | Config node cannot communicate with canister. | 1034 |
085204 | W | Managed enclosure is not visible from config node. | 1042 |
085205 | W | Canister internal error. | 1705 |
085221 | I | Successful write to USB Flash Drive | n/a |
085222 | W | Write failed to USB Flash Drive | 1790 |
086001 | E | Encryption key unavailable | 1739 |
086002 | W | Encryption key on USB flash drive removed | 2550 |
086003 | W | Write to USB Flash Drive failure | 1790 |
086004 | I | Write to USB Flash Drive successful | n/a |
086005 | W | Encryption not committed | 1780 |
086006 | E | Key Server reported KMIP error | 1785 |
086007 | E | Key Server reported vendor information error | 1785 |
086008 | E | Failed to connect to Key Server | 1785 |
087001 | E | Cloud gateway service restarted | 2031 |
087002 | E | Cloud gateway service restarted too often | 1404 |
087003 | W | Cloud account SSL certificate will expire within the next 30 days | 3140 |
087004 | W | Cloud account not available, cannot resolve hostname | 1580 |
087005 | W | Cloud account not available, cannot contact cloud provider | 2310 |
087006 | W | Cloud account not available, cannot communicate with cloud provider | 2320 |
087007 | W | Cloud account not available, no matching CA certificate | 2300 |
087008 | W | Cloud account not available, no matching CA certificate | 2300 |
087009 | W | Cloud account not available, cannot establish secure connection with cloud provider | 3100 |
087010 | W | Cloud account not available, cannot authenticate with cloud provider | 2330 |
087011 | W | Cloud account not available, cannot obtain permission to use cloud storage | 2330 2305 |
087012 | W | Cloud account not available, cannot complete cloud storage operation | 3100 |
087013 | W | Cloud account not available, cannot access cloud object storage | 2105 |
087014 | W | Cloud account not available, incompatible object data format | 3135 |
087016 | W | Cloud account not available, cloud object storage encrypted | 1656 |
087017 | W | Cloud account not available, cloud object storage not encrypted | 1656 |
087018 | W | Cloud account not available, cloud object storage encrypted with the wrong key | 1657 |
087019 | W | No permission to use cloud storage snapshot operation | 2305 |
087020 | W | Cloud account out of space during cloud storage snapshot operation | 2125 |
087021 | W | Cannot create container object to cloud object storage during cloud snapshot operation | 2305 |
087022 | W | A cloud object could not be found during cloud snapshot operation. | 3108 |
087023 | W | A cloud object was found to be corrupt during cloud snapshot operation. | 3108 |
087024 | W | A cloud object was found to be corrupt during cloud snapshot decompression operation. | 3108 |
087025 | W | Etag integrity error during cloud snapshot operation | 3108 |
087026 | W | Internal Read error during cloud snapshot operation | 2120 |
087027 | W | Unexpected error occurred, cannot complete cloud snapshot operation | 3108 |
087028 | W | No permission to use cloud snapshot restore operation | 2305 |
087029 | W | A cloud object could not be found during a cloud snapshot restore operation | 3108 |
087030 | W | A cloud object was found to be corrupt during a cloud snapshot restore operation | 3108 |
087031 | W | A cloud object was found to be corrupt during a cloud snapshot restore decompression operation | 3108 |
087032 | W | Etag integrity error during cloud snapshot restore operation | 3108 |
087033 | W | Internal write error during cloud snapshot operation | 2120 |
087034 | W | Cannot create bad blocks on a managed disk during cloud snapshot restore operation. | 3108 |
087035 | W | Unexpected error occurred, cannot complete cloud snapshot restore operation | 3108 |
087036 | W | No permission to use cloud snapshot delete operation | 2305 |
087037 | W | A cloud object could not be found during a cloud snapshot delete operation | 3108 |
087038 | W | A cloud object was found to be corrupt during cloud snapshot delete operation | 3108 |
087039 | W | A cloud object was found to be corrupt during cloud snapshot delete decompression operation | 3108 |
087040 | W | Unexpected error occurred, cannot complete cloud snapshot delete operation | 3108 |
087044 | W | Cloud account out of space during cloud snapshot restore commit operation | 2125 |
087045 | W | Cloud account out of space during cloud snapshot delete operation | 2125 |
087046 | W | Transparent Cloud Tiering feature license limit exceeded. | 3032 |
087048 | W | Too many node restarts have occurred, cloud backup operations paused | 3104 |
087049 | W | Internal FlashCopy error on volume enabled for cloud snapshots. | 2118 |
088000 | E | An IO port cannot be started | 1300 |
088001 | E | A fibrechannel target port mode transition was not successful | 1300 |
088002 | W | Equivalent fibrechannel ports are reporting that they are connected to different fabrics | 3220 |
088003 | W | A spare node in this cluster is not providing additional redundancy | 1380 |
088004 | W | A spare node could not be automatically removed from the cluster | 3180 |