IEA076E SERIOUS CONTROLLER
HEALTH,MC=cc,TOKEN=dddd,SSID=xxxx,
DEVICE
NED=tttt.mmm.ggg.pp.ssssssssssss.uuuu,RANK|DA|INTF=iiii,
text
Explanation
The storage controller has detected a serious health condition that affects one or more devices.
In the message text: :
- MC=cc
- The message code indicating the health of the storage controller. cc is one
of the following:
- 40-BF
- Serious severity
- TOKEN=dddd
- The unique value for this logical storage subsystem (LSS). Note that the message issued for each LSS contains the same token.
- SSID=xxxx
- SSID for this subsystem.
- DEVICE NED=tttt.mmm.ggg.pp.ssssssssssss.uuuu
- Node element descriptor from the device:
- tttt
- Machine type
- mmm
- Model
- ggg
- Manufacturer
- pp
- Plant of manufacture
- ssssssssssss
- Box sequence number
- uuuu
- Identifies one of the devices in the storage control that is affected. This value is the concatenation of LSS and CCA for the reporting device.
- RANK|DA|INTF=iiii
- Identifier:
- DA
- Device Adapter ID for message codes MC=42.
- INTF
- Interface ID for message codes MC=40.
- text
- Displays the reason for the message code, which is one of the following:
- IO OPERATIONS TIMING OUT ON PPRC SECONDARY CONTROLLER
- Corresponds to serious severity message code MC = 40.
- DATA ERROR DURING MEDIA SCRUB
- Corresponds to serious severity message code MC = 41.
- LAST DEVICE ADAPTER RESET
- Corresponds to acute severity message code MC=42.
- SERVER MULTIPLE WARMSTARTS
- Corresponds to serious severity message code MC = 80.
- UNKNOWN
- For any message code not defined above.
System action
The system logs a symptom record in the LOGREC data set and continues processing.
Operator response
Please contact hardware support. | Provide logrec data set error-records to CE.
System programmer response
None.
Source
DASD device initialization/re-initialization
Module
IECCINIT (z/OS® V1R13) , IECVDMSG (z/OS V2R1)
Routing code
2, 6, 10
Descriptor code
11