MAP 3312
Use this MAP to resolve the following problem:
- Array members not at required resource address (URC 9023) for a PCIe controller
Step 3312–1
Identify the disks that are not at their required physical locations by using the error log entry and the Display Hardware Status screen. For details, see Viewing device status.
Go to Step 3312–2.
Step 3312–2
There are three
possible ways to correct the problem. Perform only one of the following
three options, listed in the order of preference:
- Locate the missing disks and install them in the correct physical
locations in the system. Then, IPL the system or logical partition
(it may be necessary to boot into Rescue mode), or reset the
adapter by performing the following:
- Find the scsi host number associated with the adapter by using the Display Hardware Status screen. For more details see Viewing the Status of Disks and Disk Arrays.
- Use the
echo 1 > /sys/class/scsi_host/hostX/reset_hostcommand to reset the adapter, where X is the scsi host number from the previous step.
- Delete the disk array. For details, see Deleting an IBM SAS RAID disk array.Attention: All data on the disk array will be lost.
- Format the remaining members of the disk array, as follows: Attention: All data on the disk array will be lost.
- Run the iprconfig utility by typing
iprconfig. - Select Work with disk unit recovery.
- Select Initialize and format disk unit.
- Select the drives you wish to format then press Enter.
- Run the iprconfig utility by typing
When the problem is resolved, go to MAP 0410: Repair Checkout in RS/6000® eServer™ pSeries Diagnostic Information for Multiple Bus Systems.