9080-MHE, 9080-MME, 9119-MHE, or 9119-MME system parts
Indexed drawings show system part numbers of each part.
System control unit
Rack assembly detail (system control unit)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 01KL141 | 1 | Front bezel (9080-MHE) | |
1 | 01KL140 | 1 | Front bezel (9080-MME) | |
1 | 00RR223 | 1 | Front bezel (9119-MHE) | |
1 | 00RR222 | 1 | Front bezel (9119-MME) | |
2 | 1 | EIA bracket (left) | ||
3 | 2 | Attaching screw for EIA bracket (left) | ||
4 | 1 | Attaching screw for hook assembly (left) | ||
5 | 00FY322 | 1 | Rail kit (left) | |
6 | 1 | Attaching screw for rail kit (left) | ||
7 | 1 | HLD bracket (left) | ||
8 | 2 | Attaching screw for HLD bracket (left) | ||
9 | 1 | HLD bracket (right) | ||
10 | 2 | Attaching screw for HLD bracket (right) | ||
11 | 00FY323 | 1 | Rail kit (right) | |
12 | 1 | Attaching screw for rail kit (right) | ||
13 | 1 | EIA bracket (right) | ||
14 | 2 | Attaching screw for EIA bracket (right) | ||
15 | 1 | Attaching screw for hook assembly (right) |
Rack assembly detail, continued (system control unit)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 52F1 | 00E2898 | 1 | System VPD card |
2 | 6B45 | 00E2327 | 1 | Control panel assembly |
3 | 1 | Service card | ||
4 | 00E3324 | 1 | DVD assembly (contains DVD and DVD sled) | |
5 | 6B44 | 00FV798 | 3 - 4 | Fan Note: Some systems support only three
fans.
|
Rack assembly detail, continued (system control unit)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 6B46 | 00E2352 | 1 | System backplane |
2 | 11 | Attaching screws for system backplane | ||
3 | 1 | Top access cover assembly |
Rack assembly detail, continued (system control unit)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 6B4D | 00E2344 | 2 - 4 | Power interface card Note: Some systems with only one system
node have two power interface cards instead of four power interface cards.
|
1 | 01AF900 | 0 - 2 | Power interface card filler Note: Power interface card fillers are used on systems with two power interface cards instead of four power interface cards.
|
|
2 | 6B48 | 00E2336 | 2 | Real time clock battery card |
3 | 6B4B | 00E2380 | 2 | Service processor card |
4 | 6B49 | 00E2365 | 2 | Clock card |
Description | Part number |
---|---|
Clock flex cable (D1L) Note: From system control unit port location U3-P1-C8-T2 to system node port location U2-P1-T7.
|
00RP855 |
Clock flex cable (D1R) Note: From system control unit port location U3-P1-C9-T1 to system node port location U2-P1-T8.
|
00RP854 |
Clock flex cable (D2L) Note: From system control unit port location U3-P1-C8-T3 to system node port location U4-P1-T7.
|
00RP857 |
Clock flex cable (D2R) Note: From system control unit port location U3-P1-C9-T4 to system node port location U4-P1-T8.
|
00RP856 |
Clock flex cable (D3L) Note: From system control unit port location U3-P1-C8-T4 to system node port location U5-P1-T7.
|
00RP859 |
Clock flex cable (D3R) Note: From system control unit port location U3-P1-C9-T3 to system node port location U5-P1-T8.
|
00RP858 |
Clock flex cable (D4L) Note: From system control unit port location U3-P1-C8-T1 to system node port location U1-P1-T7.
|
00RP861 |
Clock flex cable (D4R) Note: From system control unit port location U3-P1-C9-T2 to system node port location U1-P1-T8.
|
00RP860 |
Global flexible service processor (GFSP) 1 m cable | 00FX191 |
UPIC cable to system control unit (long) | 00FX185 |
UPIC cable to system control unit (short) | 00FX186 |
USB cable for DVD | 00FX908 |
System node
Rack final assembly (system node)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 01KL139 | 1 | Front bezel (9080-MHE) | |
1 | 01KL138 | 1 | Front bezel (9080-MME) | |
1 | 00RR113 | 1 | Front bezel (9119-MHE) | |
1 | 00RR112 | 1 | Front bezel (9119-MME) | |
2 | 1 | Hook assembly (left) | ||
3 | 1 | Attaching screw for hook assembly (left) | ||
4 | 1 | EIA bracket (left) | ||
5 | 3 | Attaching screw for EIA bracket (left) | ||
6 | 00RP979 | 1 | Rail kit (left) | |
7 | 1 | Attaching screw for rail kit (left) | ||
8 | 2 | EIA stiffener | ||
9 | 2 | Attaching screws for EIA stiffener | ||
10 | 1 | Cable management bracket (left) | ||
10 | 1 | Cable management bracket (right) | ||
10 | 1 | Cable management horizontal bracket | ||
10 | 2 | Double-gated carabiner | ||
10 | 2 | Attaching screws for cable management brackets | ||
11 | 8 | Attaching screws for cable management arm assembly | ||
11 | 2 | Attaching screws for cable management arm assembly | ||
12 | 00RP980 | 1 | Rail kit (right) | |
13 | 1 | Attaching screw for rail kit (right) | ||
14 | 1 | Hook assembly (right) | ||
15 | 46K4480 | 1 | Attaching screw for hook assembly (right) | |
16 | 1 | EIA bracket (right) | ||
17 | 3 | Attaching screw for EIA bracket (right) |
Rack assembly detail, continued (system node)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 00FV898 | 1 | Front line cord conduit (left) Note: To replace the complete line cord
conduit, you must also order the part number for the left rear line cord conduit. For information
about the left rear line cord conduit, see table
10.
|
|
2 | 6B42 | 00E9335 | 5 | Fan |
3 | 00FV902 | 1 | Front line cord conduit (right) Note: To replace the complete line cord
conduit, you must also order the part number for the right rear line cord conduit. For information
about the right rear line cord conduit, see table
10.
|
|
4 | 51D2 | 00FX964 | 4 | Power supply |
Rack assembly detail, continued (system node)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 1 | Top access cover assembly | ||
2 | 31E8 | 00VK193 | 0 - 32 | 16 GB CDIMM DDR3* |
2 | 31EC | 00VK252 | 0 - 32 | 16 GB CDIMM
DDR4* Note: System
firmware FW860.10 or later is required to support DDR4 memory on a 9080-MHE, 9080-MME,
9119-MHE, or 9119-MME system.
|
2 | 31E9 | 00VK195 | 0 - 32 | 32 GB CDIMM DDR3* |
2 | 31ED | 00VK296 | 0 - 32 | 32 GB CDIMM
DDR4* Note: System
firmware FW860.10 or later is required to support DDR4 memory on a 9080-MHE, 9080-MME,
9119-MHE, or 9119-MME system.
|
2 | 31EA | 00VK197 | 0 - 32 | 64 GB CDIMM DDR3* |
2 | 31EE | 00VK306 | 0 - 32 | 64 GB CDIMM
DDR4* Note: System
firmware FW860.10 or later is required to support DDR4 memory on a 9080-MHE, 9080-MME,
9119-MHE, or 9119-MME system.
|
2 | 31EB | 00VK198 | 0 - 32 | 128 GB CDIMM DDR3* |
2 | 31EF | 00VK351 | 0 - 32 | 128 GB CDIMM
DDR4* Note: System
firmware FW860.10 or later is required to support DDR4 memory on a 9080-MHE, 9080-MME,
9119-MHE, or 9119-MME system.
|
2 | 31FC | 00VK242 | 0 - 32 | 256 GB CDIMM DDR4* Note: System firmware FW860.10 or later is
required to support DDR4 memory on a 9080-MHE, 9080-MME,
9119-MHE, or 9119-MME
system.
|
2 | 00FW989 | 0 - 32 | CDIMM filler | |
3 | 6B31 | 00RP695 | 4 | Processor voltage regulator module |
4 | 6B32 | 00RP696 | 6 | Memory voltage regulator module |
4 | 6B33 | 00RP698 | 2 | Memory buffer voltage regulator module |
4 | 6B34 | 00RP699 | 1 | Vpp voltage regulator module |
4 | 6B35 | 00RP697 | 1 | Miscellaneous voltage regulator module |
5 | 6B28 | 00E2578 | 2 | Power APSS card |
*You can install DDR3 and DDR4 memory within a single system as long as all of the memory within each system node is the same type and your system has firmware FW860.10 or later. |
Rack assembly detail, continued (system node)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 00RR232 | 4 | Heat sink | |
2 | 54EF | 00RR140 | 4 | 8 core 4.35 GHz processor module (9080-MHE and 9119-MHE) |
2 | 54EE | 00RR143 | 4 | 8 core 4.02 GHz processor module (9080-MME and 9119-MME) |
2 | 550B | 00RR137 | 4 | 10 core 4.19 GHz processor module (9080-MHE, 9119-MHE, and 9119-MME) |
2 | 550C | 02CM167 | 4 | 10 core 4.02 GHz processor module (9080-MHE and 9119-MHE) Note: The 10 core and 12 core 4.02 GHz processor
modules have the same CCIN but different part numbers. Order the part number that has the same
number of cores as the processor that you are replacing.
|
2 | 550C | 00RR176 | 4 | 12 core 4.02 GHz processor module (9080-MHE and 9119-MHE) Note: The 10 core and 12 core 4.02 GHz processor
modules have the same CCIN but different part numbers. Order the part number that has the same
number of cores as the processor that you are replacing.
|
3 | 00E2494 | 1 | System backplane |
Rack assembly detail, continued (system node)
Index number | CCIN | Part number | Units per assembly | Description |
---|---|---|---|---|
1 | 6B29 | 00E2608 | 8 | I/O blind swap cassette with PCIe extender card |
2 | 1 - 8 | PCI adapters. Use the CCIN or feature type of the adapter to find the FRU number in PCI adapter information by feature type. | ||
3 | 1 | Service information card | ||
4 | 6B2E | 00E2598 | 2 | GFSP interface card |
5 | 00FV915 | 1 | AC rear line cord conduit
(right) Note: To replace the
complete line cord conduit, you must also order the part number for the right front line cord
conduit. For information about the right front line cord conduit, see table 7.
|
|
5 | 01AF309 | 1 | DC rear line cord conduit (right) Note: To replace the complete line cord
conduit, you must also order the part number for the right front line cord conduit. For information
about the right front line cord conduit, see table
7.
|
|
6 | 00FV906 | 1 | AC rear line cord conduit
(left) Note: To replace the
complete line cord conduit, you must also order the part number for the left front line cord
conduit. For information about the left front line cord conduit, see table 7.
|
|
6 | 01AF308 | 1 | DC rear line cord conduit (left) Note: To replace the complete line cord
conduit, you must also order the part number for the left front line cord conduit. For information
about the left front line cord conduit, see table
7.
|
|
7 | 6B2D | 00E2394 | 2 | Local clock card |
Description | Part number |
---|---|
PDU power cables | See Supported PDU power cords. |
Clock flex cable (D1L) Note: From system control unit port location U3-P1-C8-T2 to system node port location U2-P1-T7.
|
00RP855 |
Clock flex cable (D1R) Note: From system control unit port location U3-P1-C9-T1 to system node port location U2-P1-T8.
|
00RP854 |
Clock flex cable (D2L) Note: From system control unit port location U3-P1-C8-T3 to system node port location U4-P1-T7.
|
00RP857 |
Clock flex cable (D2R) Note: From system control unit port location U3-P1-C9-T4 to system node port location U4-P1-T8.
|
00RP856 |
Clock flex cable (D3L) Note: From system control unit port location U3-P1-C8-T4 to system node port location U5-P1-T7.
|
00RP859 |
Clock flex cable (D3R) Note: From system control unit port location U3-P1-C9-T3 to system node port location U5-P1-T8.
|
00RP858 |
Clock flex cable (D4L) Note: From system control unit port location U3-P1-C8-T1 to system node port location U1-P1-T7.
|
00RP861 |
Clock flex cable (D4R) Note: From system control unit port location U3-P1-C9-T2 to system node port location U1-P1-T8.
|
00RP860 |
Global flexible service processor (GFSP) 1 m cable | 00FX191 |
SMP 1.25 m cable | 46K3418 |
SMP 1.5 m cable | 46K3419 |
UPIC cable to system control unit (long) | 00FX185 |
UPIC cable to system control unit (short) | 00FX186 |
Description | Part number |
---|---|
Cable configuration | See Enclosures and Expansion Units. |
External cables and cords | See Planning for cables. |
Power and UPS cables | See Planning for power. |
Keyboard parts | See Keyboard parts. |
Removable media | See Managing devices. |